Mostrar el registro sencillo del ítem

dc.contributor.authorAlonso Rivas, Eduardoes-ES
dc.contributor.authorMatanza Domingo, Javieres-ES
dc.contributor.authorRodríguez-Morcillo García, Carloses-ES
dc.contributor.authorAlexandres Fernández, Sadotes-ES
dc.date.accessioned2016-01-15T11:25:58Z
dc.date.available2016-01-15T11:25:58Z
dc.date.issued29/03/2015es_ES
dc.identifier.urihttp://hdl.handle.net/11531/5463
dc.descriptionCapítulos en libroses_ES
dc.description.abstractes-ES
dc.description.abstractPLC is gaining prominence as a solution for Smart Grid developments. However, several aspects still require further research and analysis. Among the different solutions, PRIME (PoweRline Intelligent Metering Evolution) standard is one of the most popular and extended implementations. This paper analyses the performance impact caused by the polling strategy utilized in an auto meter reading (AMR) process for a PRIME PLC network. In particular, the number of connections that the master node is able to manage simultaneously is studied. The time required to read all the meters in the network is utilized as performance metric. In order to replicate the performance of a PRIME s network, a co-simulation framework that combines Matlab and OMNeT++ has been used. This architecture allows to take into account both physical phenomena and control and application message management. Simulated topologies represent a general European low-voltage network. Results highlight the importance of selecting an adequate number of simultaneous connections in order to optimize the use of the channel.en-GB
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoen-GBes_ES
dc.publisherIEEE Technical Committee on Power Line Communications (Austin, Estados Unidos de América)es_ES
dc.rightses_ES
dc.rights.uries_ES
dc.sourceLibro: IEEE International Symposium on Power Line Communications and Its Applications - ISPLC 2015, Página inicial: 101-106, Página final:es_ES
dc.subject.otherInstituto de Investigación Tecnológica (IIT)es_ES
dc.titlePerformance evaluation of AMR simultaneous polling strategies in a PRIME PLC networkes_ES
dc.typeinfo:eu-repo/semantics/bookPartes_ES
dc.description.versioninfo:eu-repo/semantics/publishedVersiones_ES
dc.rights.accessRightsinfo:eu-repo/semantics/restrictedAccesses_ES
dc.keywordses-ES
dc.keywordsPower Line Communication; PRIME; polling strategy; OMNeT++; European LV Distribution Network; time to read meters.en-GB


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

  • Artículos
    Artículos de revista, capítulos de libro y contribuciones en congresos publicadas.

Mostrar el registro sencillo del ítem