Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/11531/108411
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorCedenilla Bote, Alejandraes-ES
dc.contributor.authorRouco Rodríguez, Luises-ES
dc.contributor.authorSigrist, Lukases-ES
dc.contributor.authorCarpentier, Philippees-ES
dc.contributor.authorGuironnet, Adrienes-ES
dc.contributor.authorTorresan, Gilleses-ES
dc.date.accessioned2026-01-28T10:24:41Z-
dc.date.available2026-01-28T10:24:41Z-
dc.identifier.urihttp://hdl.handle.net/11531/108411-
dc.description.abstractes-ES
dc.description.abstractInter-area oscillations are a major challenge for power systems, as they can lead to system instability if they are not damped. To prevent such, restrictions on power transmission over specific lines are often necessary, which in turn incur significant economic costs. This justifies the need to improve the tuning of Power Oscillation Damping Controllers (PODs). PODs can be implemented in synchronous generators, FACTS devices, HVDC links, and BESSs.Lead-lag controllers are widely used in the industry for their simplicity and effectiveness. The eigenvalue sensitivity method applied to the tuning of lead-lag controllers, enables direct determination of controller parameters, making the method particularly efficient for practical applications.With the eigenvalue sensitivity method, the trajectory of the eigenvalue is assumed to be linear and defined by the sensitivity calculated for the initial position of the eigenvalue. However, the eigenvalue trajectory is not necessarily linear and may deviate from the sensitivity, especially in the case of high gain values.In response to these limitations, this work introduces two approaches to optimize both the gain and the structure of a POD tuned using the sensitivity method. A well-known study case is used to illustrate the sensitivity method's limitations and the proposed solutions' effectiveness.en-GB
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoen-GBes_ES
dc.rightses_ES
dc.rights.uries_ES
dc.titleImproved Eigenvalue Sensitivity Method for Designing Power System Damping Controllerses_ES
dc.typeinfo:eu-repo/semantics/workingPaperes_ES
dc.description.versioninfo:eu-repo/semantics/draftes_ES
dc.rights.accessRightsinfo:eu-repo/semantics/restrictedAccesses_ES
dc.keywordses-ES
dc.keywordsController Design, Eigenvalue Sensitivity, Oscillation Damping, Small-Signal Stability.en-GB
Aparece en las colecciones: Documentos de Trabajo

Ficheros en este ítem:
Fichero Tamaño Formato  
IIT-25-400C.pdf859,3 kBAdobe PDFVisualizar/Abrir     Request a copy


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.