Por favor, use este identificador para citar o enlazar este ítem:
http://hdl.handle.net/11531/110115Registro completo de metadatos
| Campo DC | Valor | Lengua/Idioma |
|---|---|---|
| dc.contributor.advisor | Mirabal Montero, Santiago | es-ES |
| dc.contributor.author | Vicario De Miguel, José Javier | es-ES |
| dc.contributor.other | Universidad Pontificia Comillas, Escuela Técnica Superior de Ingeniería (ICAI) | es_ES |
| dc.date.accessioned | 2026-05-18T09:43:57Z | - |
| dc.date.available | 2026-05-18T09:43:57Z | - |
| dc.date.issued | 2026 | es_ES |
| dc.identifier.uri | http://hdl.handle.net/11531/110115 | - |
| dc.description | Grado en Ingeniería en Tecnologías Industriales | es_ES |
| dc.description.abstract | El presente trabajo estima la demanda eléctrica de un desarrollo urbanístico de nueva planta compuesto por tres ámbitos de planeamiento: un centro de negocios (APE 05.31), una zona mixta residencial (APE 08.20) y una zona mixta comercial (APE 08.21). El objetivo es determinar la infraestructura eléctrica necesaria para el suministro y cuantificar el ahorro que permite la eficiencia energética. La metodología se basa en la aplicación de ratios de potencia por uso establecidos en el Reglamento Electrotécnico para Baja Tensión (ITC-BT-10) para construir un escenario de partida. Sobre ese mismo ámbito y superficies se define un escenario eficiente que aplica reducciones por partida (iluminación, equipamiento y climatización) coherentes con el Código Técnico de la Edificación, el Reglamento de Instalaciones Térmicas en los Edificios (RITE) y la normativa europea de etiquetado energético y ecodiseño. El cálculo se realiza de forma desagregada por partida y por zona, permitiendo identificar el peso relativo de cada uso en la demanda total. Los resultados muestran que la eficiencia energética reduce la demanda total del desarrollo en un 22,8 %, pasando de 314,6 MVA a 243,0 MVA. Esta reducción permite dimensionar las subestaciones de 220/20 kV con cinco transformadores de 50 MVA en lugar de siete, lo que supone evitar dos unidades y un ahorro de inversión del orden de 6 millones de euros. El efecto se reproduce también en distribución, donde el número de centros de transformación de 400 kVA se reduce en torno a un 23 %. La robustez se verifica mediante un análisis de sensibilidad sobre la reducción de equipamiento en el rango del 30 % al 50 %, comprobando que el número de transformadores y el ahorro estimado se mantienen en todos los casos. Toda la justificación se apoya en fuentes normativas públicas y verificables, garantizando la trazabilidad del modelo. | es-ES |
| dc.description.abstract | This work estimates the electrical demand of a new urban development comprising three planning areas: a business centre (APE 05.31), a mixed residential zone (APE 08.20) and a mixed commercial zone (APE 08.21). The aim is to determine the electrical infrastructure required for supply and to quantify the savings enabled by energy efficiency. The methodology applies power ratios by land use from the Low Voltage Electrotechnical Regulations (ITC-BT-10) to establish a baseline scenario. An efficient scenario is then defined over the same areas and floor surfaces, applying per-category reductions (lighting, equipment and HVAC) consistent with the Spanish Technical Building Code, the Thermal Installations Regulations (RITE) and European energy labelling and ecodesign legislation. Calculations are disaggregated by category and by zone, making it possible to identify the relative contribution of each use to total demand. Results show that energy efficiency reduces total demand by 22.8 %, from 314.6 MVA to 243.0 MVA. This reduction allows the 220/20 kV substations to be sized with five 50 MVA transformers instead of seven, avoiding two units and yielding an investment saving of approximately 6 million euros. The effect also extends to distribution level, where the number of 400 kVA transformer substations is reduced by approximately 23 %. The robustness of the conclusions is verified through a sensitivity analysis on the equipment reduction parameter, varied across a range of 30 % to 50 %, confirming that the transformer count and estimated savings remain unchanged throughout. All justifications rely on publicly available regulatory sources, ensuring full traceability of the model. | en-GB |
| dc.format.mimetype | application/pdf | es_ES |
| dc.language.iso | es-ES | es_ES |
| dc.rights | Attribution-NonCommercial-NoDerivs 3.0 United States | es_ES |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/us/ | es_ES |
| dc.subject.other | KTI-electricidad (GITI-E) | es_ES |
| dc.title | Estimación de la demanda eléctrica en Madrid Nuevo Norte. Evaluación de escenarios y optimización de demanda conforme a la normativa europea y española relativa a la eficiencia energética. | es_ES |
| dc.type | info:eu-repo/semantics/bachelorThesis | es_ES |
| dc.rights.accessRights | info:eu-repo/semantics/openAccess | es_ES |
| dc.keywords | demanda eléctrica; eficiencia energética; planificación urbanística; transformadores de potencia; normativa energética | es-ES |
| dc.keywords | electrical demand; energy efficiency; urban planning; power transformers; energy regulations | en-GB |
| Aparece en las colecciones: | TFG, TFM (temporales) | |
Ficheros en este ítem:
| Fichero | Descripción | Tamaño | Formato | |
|---|---|---|---|---|
| TFG - Vicario de Miguel Jose Javier.pdf | Trabajo Fin de Grado | 3,22 MB | Adobe PDF | Visualizar/Abrir |
| Anexo I Javier Vicario.pdf | Autorización | 380,8 kB | Adobe PDF | Visualizar/Abrir |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.