Por favor, use este identificador para citar o enlazar este ítem:
http://hdl.handle.net/11531/26644
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.advisor | Martínez Beltrán, María Jesús | - |
dc.contributor.author | Sánchez-Pascuala Sánchez-Pascuala, Lara | - |
dc.contributor.other | Universidad Pontificia Comillas, Escuela Universiaria de Enfermería Y Fisioterapia | es_ES |
dc.date.accessioned | 2018-04-24T09:33:01Z | - |
dc.date.available | 2018-04-24T09:33:01Z | - |
dc.date.issued | 2016 | - |
dc.identifier.uri | http://hdl.handle.net/11531/26644 | - |
dc.description | Titulación::Postgrado::Máster Universitario en Biomecánica y Fisioterapia Deportiva | es_ES |
dc.description.abstract | Antecedentes: El síndrome de dolor miofascial es una de las causas principales de alteraciones musculoesqueléticas. Este síndrome se caracteriza por la presencia de puntos gatillo miofasciales. Hay varios criterios diagnósticos para su detección, tales como la dinamometría y la electromiografía de superficie. Uno de los tratamientos que está en auge actualmente es el vendaje neuromuscular. Objetivos: Valorar la influencia de la aplicación de un VNM frente a un vendaje placebo en la variación de la fuerza máxima y la actividad electromiográfica en pacientes con un punto gatillo miofascial en el músculo trapecio superior. Metodología: Estudio piloto experimental con 20 pacientes. Al grupo A (grupo experimental) se le aplicó un vendaje neuromuscular y al grupo B (grupo control), un vendaje placebo. Se localizó un punto gatillo en el músculo trapecio superior. Se realizaron dos mediciones mediante dinamometría y electromiografía de superficie, una primera medición se realizó previamente a la intervención, la segunda se llevó a cabo 24 horas después de la misma. Se efectuó un análisis descriptivo de las variables de estudio. Por otra parte, se realizó un contraste de hipótesis mediante la prueba U de Mann-Whitney, para muestras independientes de cada variable. Conclusiones: No existen diferencias estadísticamente significativas entre la aplicación de un vendaje neuromuscular y un placebo en la variación de los valores de fuerza máxima isométrica, ni en la actividad electromiográfica en el ascenso de hombro sobre un punto gatillo miofasical en el músculo trapecio superior. | es_ES |
dc.description.abstract | Introduction: Myofascial pain syndrome is one of the causes of musculoskeletal disorders. This syndrome is characterized by the presence of myofascial trigger points. The muscle in the greatest number of trigger points are diagnosed is the upper trapezius. There are several diagnostic criteria for his detection, such as dynamometry and surface electromyography. Currently one of the most widely used treatments is the neuromuscular tape. Objectives: To assess the effects of the application of a neuromuscular tape versus placebo in the variation of the force and electromyographic activity in patients with myofascial trigger point in upper trapezius muscle. Methodology: Experimental pilot study with 20 patients. A neuromuscular tape was applied to group A (experimental group) and group B (control group) received a placebo tape. After an evaluation, a trigger point was located in the upper trapezius muscle. Two measurements were made using surface electromyography and a dynamometer. The first measurement is performed previously to the intervention; the second measurement was carried out 24 hours after the intervention. A descriptive analysis of the study variables was performed. Moreover, a test of hypothesis was made using the Mann-Whitney U test for independent samples for each variable. Conclusions: There are no statistically significant differences between the application of a neuromuscular tape and a placebo tape on the variation of the values of maximal isometric strength, or electromyographic activity in the rise of shoulder on a myofascial trigger point in the upper trapezius muscle. | es_ES |
dc.format.mimetype | application/pdf | es_ES |
dc.language.iso | es | es_ES |
dc.subject | UNESCO::32 Medicina::3213 Cirugía::321311 Fisioterapia | es_ES |
dc.subject | UNESCO::24 Ciencias de la vida::2402 Antropología física::240203 Antropometría y antropología forense | es_ES |
dc.subject | UNESCO::24 Ciencias de la vida::2411 Fisiología humana::241111 Neurofisiología | es_ES |
dc.subject | UNESCO::24 Ciencias de la vida::2411 Fisiología humana::241110 Fisiología del músculo | es_ES |
dc.title | Variación de los datos de actividad electromiográfica y de fuerza tras la aplicación de vendaje neuromuscular en un punto gatillo miofascial latente | es_ES |
dc.type | info:eu-repo/semantics/masterThesis | es_ES |
dc.rights.accessRights | info:eu-repo/semantics/closedAccess | es_ES |
dc.keywords | Punto gatillo latente, Dinamómetro, Electromiografía de superficie, Vendaje neuromuscular | es_ES |
dc.keywords | Latent trigger point, Dynamometer, Surface electromyography, Neuromuscular tape | es_ES |
Aparece en las colecciones: | H78 -Trabajos Fin de Máster |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
PFM000131.pdf | Proyecto Fin de Máster | 1,62 MB | Adobe PDF | Visualizar/Abrir Request a copy |
PFM000131.pdf | Autorización | 4,5 MB | Adobe PDF | Visualizar/Abrir Request a copy |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.