Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/11531/26646
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorParís Zamora, Irene-
dc.contributor.advisorPérez Mallada, Néstor-
dc.contributor.advisorSaenz Nuño, María Ana-
dc.contributor.authorPedraza Carballo, Mª Gema-
dc.contributor.otherUniversidad Pontificia Comillas, Escuela Universiaria de Enfermería Y Fisioterapiaes_ES
dc.date.accessioned2018-04-24T09:48:23Z-
dc.date.available2018-04-24T09:48:23Z-
dc.date.issued2016-
dc.identifier.urihttp://hdl.handle.net/11531/26646-
dc.descriptionTitulación::Postgrado::Máster Universitario en Biomecánica y Fisioterapia Deportivaes_ES
dc.description.abstractANTECEDENTES: Este trabajo entra a formar parte de un estudio multidisciplinario integrado por ingeniería, biología, medicina, física y por su puesto fisioterapia, que pretende dar al ámbito de la salud la importancia de la trazabilidad metrólogica que se debe y que hasta ahora, no se ha dado. Son pocos los estudios que, a este respecto, intentan verificar y dar validez a las medidas que dan base a la ciencia médica. Para ello se elige la modalidad de tomografía computarizada (TC) por ser actualmente una de las modalidades radiológicas con más indicaciones para la valoración del tejido óseo y obtención de medidas con uso clínico. OBJETIVOS: comparar medidas obtenidas con la TC con unas medidas de referencia obtenidas en FREMAP y acreditado por el CEM para verificar su valor. METODOLOGÍA: Estudio pionero, observacional, cuantitativo y transversal, realizado en el Hospital Universitario de Fuenlabrada, que obtiene medidas realizadas sobre una imagen de un patrón de estructura ósea y marcadores metálicos y obtenidas mediante la modalidad radiológica de TC con protocolo específico de hueso Se realizan distintas adquisiciones de imágenes en función de la posición del patrón en la mesa de la TC y del apoyo sobre distintos planos. Para el estudio estadístico se selecciona las medidas de mayor frecuencia y se realiza un estudio descriptivo e inferencial y de comparación de medias entre las medidas resultantes y las de referencia con la T de Student. CONCLUSIONES: No existen variaciones estadísticas significativas entre las medidas obtenidas por TC y las dadas por el CEM. No existen variaciones estadísticas significativas en función de la posición de mesa y apoyo de distintos planos.es_ES
dc.description.abstractINTRODUCTION: This project becomes part of a team of this multidisciplinary study, integrated by: engineering, biology, medicine, physics and of course physiotherapy, which aims to give to the health field the importance that metrological traceability should have, and has not until now. There are few studies, in this regard, trying to verify and validate the measures, which give base to the medical science. Because of that computed tomography (TC) modality has been chosen, for being currently one of the radiologic modalities with more indications for the evaluation of bone tissue and obtaining measurements with clinical use. OBJETIVES: compare measurements obtained with TC with the reference measurements obtained in FREMAP and accredited by the CEM to verify its value. METHODOLOGY: Pioneer, cross-sectional observational and quantitative study conducted at the University Hospital of Fuenlabrada, which compares measurements made over an image of a pattern of bone structure and metal markers and obtained by the TC radiologic modality with a specific protocol bone, different image acquisitions are made depending on the position of the pattern on the TC table and the position on various planes. For the statistical study, measures which appear more often have been selected and is performed a descriptive and inferential study and the comparison of means between the resulting measurements and the reference ones with T-Student test. CONCLUSIONS: No statistically significant variations exist between the measurements obtained by TC and those given by the CEM. There are no statistically significant variations depending on the position nor on the table nor on different planes.es_ES
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoeses_ES
dc.subjectUNESCO::32 Medicina::3213 Cirugía::321311 Fisioterapiaes_ES
dc.subjectUNESCO::24 Ciencias de la vida::2402 Antropología física::240203 Antropometría y antropología forensees_ES
dc.subjectUNESCO::32 Medicina::3201 Ciencias clínicas::320111 Radiologíaes_ES
dc.titleComparativa entre las medidas realizadas por el Centro Nacional de Metrología y las obtenidas por TC con protocolo de huesoes_ES
dc.typeinfo:eu-repo/semantics/masterThesises_ES
dc.rights.accessRightsinfo:eu-repo/semantics/closedAccesses_ES
dc.keywordsTomografía Computarizada (TC), Patrón, Medidases_ES
dc.keywordsComputed tomography, Standard, Measureses_ES
Aparece en las colecciones: H78 -Trabajos Fin de Máster

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
PFM000133.pdfProyecto Fin de Máster2,36 MBAdobe PDFVisualizar/Abrir     Request a copy
PFM000133.pdfAutorización568,22 kBAdobe PDFVisualizar/Abrir     Request a copy


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.