Por favor, use este identificador para citar o enlazar este ítem:
http://hdl.handle.net/11531/26647
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.advisor | García González, Adela | - |
dc.contributor.author | Balaguer Gómez, Silvia | - |
dc.contributor.other | Universidad Pontificia Comillas, Escuela Universiaria de Enfermería Y Fisioterapia | es_ES |
dc.date.accessioned | 2018-04-24T09:55:04Z | - |
dc.date.available | 2018-04-24T09:55:04Z | - |
dc.date.issued | 2016 | - |
dc.identifier.uri | http://hdl.handle.net/11531/26647 | - |
dc.description | Titulación::Postgrado::Máster Universitario en Biomecánica y Fisioterapia Deportiva | es_ES |
dc.description.abstract | Introducción: En este estudio se ha realizado una evaluación de la fuerza muscular, la potencia y el tiempo que se tarda en alcanzar el pico máximo de fuerza en los movimientos de abducción en mujeres sanas, con el objetivo de obtener datos normativos y por otro lado evaluar las diferencias que puede haber entre hombro dominante y no dominante. Material y métodos: Estudio piloto observacional de corte transversal. Se han tomado medidas a 30 mujeres, tanto el hombro dominante como el no dominante en los movimientos de abducción con dinamómetro isocinético BTE PrimusRs, con el objetivo de sacar datos sobre Fuerza media Máxima isométrica, potencia y tiempo en alcanzar el pico máximo de fuerza. Se llevó a cabo un análisis descriptivo de las variables de estudio y para el contraste de hipótesis su utilizó la prueba t de Student para muestras relacionadas, asumiendo un valor de p<0.05. Resultados: No existen diferencias estadísticamente significativas entre brazo dominante y no dominante en lo que respecta a la fuerza media máxima isométrica y la potencia en los movimientos de abducción en mujeres sanas medidas con dinamómetro. No ocurre lo mismo con el tiempo en alcanzar el pico máximo de fuerza, siendo mayor en el dominante. Conclusión: No se han encontrado datos que permitan pensar que existen diferencias entre el brazo dominante y el no dominante con respecto a la fuerza muscular isométrica y la potencia en mujeres sanas. | es_ES |
dc.description.abstract | Introduction: This study has carried out the evaluation of muscular strength, power and time in which it takes healthy women to reach the maximum peak of strength in abduction movements, so as to obtain normative data as well as evaluate the differences between the dominant and non-dominant shoulders. Material and methods: Pilot observational cross-sectional study. Measures have been taken from 30 women, for both the dominant and non-dominant shoulders in abduction movements, using a BTE PrimusRS Isokinetic dynamometer, in order to obtain data regarding Maximum Isometric Force, power and time to reach the maximum peak of strength. A descriptive analysis was performed about the variables of study and Student’s t-test was used for the contrast of hypothesis in related samples, having a p<0.05 value. Results: There are no statistically significant differences between dominant and nondominant shoulders of healthy women regarding Force and power in abduction movements measured with a dynamometer. The same does not occur with the time needed to reach the maximum peak of strength, in which it is higher in the dominant shoulder. Conclusion: No found evidence to suggest that there are differences between the dominant and non-dominant arm with respect to the isometric muscle strength and power in healthy women. | es_ES |
dc.format.mimetype | application/pdf | es_ES |
dc.language.iso | es | es_ES |
dc.subject | UNESCO::32 Medicina::3213 Cirugía::321311 Fisioterapia | es_ES |
dc.subject | UNESCO::24 Ciencias de la vida::2402 Antropología física::240203 Antropometría y antropología forense | es_ES |
dc.subject | UNESCO::24 Ciencias de la vida::2411 Fisiología humana::241110 Fisiología del músculo | es_ES |
dc.subject | UNESCO::24 Ciencias de la vida::2411 Fisiología humana::241118 Fisiología del movimiento | es_ES |
dc.title | Medición de la fuerza muscular del hombro con dinamometría en mujeres sanas | es_ES |
dc.type | info:eu-repo/semantics/masterThesis | es_ES |
dc.rights.accessRights | info:eu-repo/semantics/closedAccess | es_ES |
dc.keywords | Fuerza muscular, Potencia, Dinamómetro isocinético, Abducción | es_ES |
dc.keywords | Muscle strength, Power, Isokinetic dynamometer, Abduction | es_ES |
Aparece en las colecciones: | H78 -Trabajos Fin de Máster |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
PFM000134.pdf | Proyecto Fin de Máster | 1,59 MB | Adobe PDF | Visualizar/Abrir Request a copy |
PFM000134.pdf | Autorización | 201,82 kB | Adobe PDF | Visualizar/Abrir Request a copy |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.