Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/11531/35088
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorLópez Moreno, Carlos-
dc.contributor.authorCallejas Romero, José Antonio-
dc.contributor.otherUniversidad Pontificia Comillas, Escuela Universiaria de Enfermería Y Fisioterapiaes_ES
dc.date.accessioned2019-02-05T10:27:12Z-
dc.date.available2019-02-05T10:27:12Z-
dc.date.issued2018-
dc.identifier.urihttp://hdl.handle.net/11531/35088-
dc.descriptionTitulación::Postgrado::Máster Universitario en Biomecánica y Fisioterapia Deportivaes_ES
dc.description.abstractEl hombro es un conjunto de articulaciones muy complejo, dotado de una gran capacidad de movimiento. Estas características suponen también una gran sensibilidad a cambios o alteraciones en sus estructuras y, por consiguiente, un alto riesgo de lesión, estando entre las tres primeras causas de consulta médica por alteraciones del sistema musculoesquelético. Son muchos los estudios que hablan de la importancia de la valoración del rango articular (ROM) en el tratamiento y prevención de lesiones en el ámbito laboral y deportivo. Los nuevos goniómetros digitales son una alternativa real a las herramientas de medición usadas durante los últimos años. Son dispositivos pequeños, de uso sencillo y accesibles a nivel económico. Objetivo: Validar el goniómetro digital HCT Hawk como herramienta de medida para la flexión de hombro, calcular el error de medición del aparato y verificar su precisión comparado con el sistema de valoración isocinético BTE PrimusRS. Diseño: Se lleva a cabo un estudio cuantitativo analítico con un único sujeto que realiza los movimientos de flexión de hombro. Se recogen datos de ROM y velocidad (V) de forma simultánea en ambos dispositivos que serán comparados y analizados estadísticamente mediante el software IBM SPSS Statistics. Conclusiones: Se obtienen datos de correlación de 0,942 y un nivel de significación de 0.00 para la variable ROM. En cuanto a la variable V, la diferencia entre herramientas es inferior a 0.5º/s. El error en la medida de V es prácticamente nulo. El goniómetro digital HCT Hawk es una herramienta fiable para la valoración del movimiento de flexión de hombro.es_ES
dc.description.abstractThe shoulder is a complex set of joints with a great movement capability. These characteristics makes it really sensitive to changes in their structures and suppose a high injury risk, being among the first three causes of musculoskeletal system alterations. Many studies talk about the range of motion (ROM) measurement importance in treatment and injuries prevention for workers and sport players. New digital goniometers are a great alternative for traditional measurement tools. They’re small, easy to use and not too expensive devices. Objective: To validate the HCT Hawk digital goniometer as an acurate measurement tool for shoulder flexion, compared to the BTE PrimusRS isokinetic dynamometer. Design: A quantitative analytical study is carried out with a single subject that performs movements of shoulder flexion. Data of ROM and veocity (V) are collected simultaneously in both devices, compared and statistically analyzed using the IBM SPSS Statistics software. Conclusions: Data about ROM shows correlation of 0.942 and a significance level of 0.00. About V, the difference between tools is less than 0.5º/s. HCT Hawk digital goniometer is a reliable rating tool shoulder flexion movement.es_ES
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoeses_ES
dc.subjectUNESCO::24 Ciencias de la vida::2406 Biofísica::240604 Biomecánicaes_ES
dc.subjectUNESCO::24 Ciencias de la vida::2402 Antropología física::240203 Antropometría y antropología forensees_ES
dc.subjectUNESCO::32 Medicina::3213 Cirugía::321311 Fisioterapiaes_ES
dc.titleValidación del goniómetro digital Hawk HCT en la medición del balance articular y velocidad de la flexión de hombroes_ES
dc.typeinfo:eu-repo/semantics/masterThesises_ES
dc.rights.accessRightsinfo:eu-repo/semantics/closedAccesses_ES
dc.keywordsGoniómetro digital, ROM, Velocidad, Hombro, Dinamómetro isocinéticoes_ES
dc.keywordsDigital goniometer, ROM, Velocity, Shoulder, Isokinetic dynamometeres_ES
Aparece en las colecciones: H78 -Trabajos Fin de Máster

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
PFM000176.pdfProyecto Fin de Máster4,08 MBAdobe PDFVisualizar/Abrir     Request a copy
PFM000176.pdfAutorización579,62 kBAdobe PDFVisualizar/Abrir     Request a copy


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.