Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/11531/35137
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorBlanco Méndez, Ricardo-
dc.contributor.authorSancho Montero, Miriam-
dc.contributor.otherUniversidad Pontificia Comillas, Escuela Universiaria de Enfermería Y Fisioterapiaes_ES
dc.date.accessioned2019-02-07T09:40:39Z-
dc.date.available2019-02-07T09:40:39Z-
dc.date.issued2018-
dc.identifier.urihttp://hdl.handle.net/11531/35137-
dc.descriptionTitulación::Postgrado::Máster Universitario en Biomecánica y Fisioterapia Deportivaes_ES
dc.description.abstractAntecedentes Como bien se conoce, los estiramientos están muy arraigados en las distintas modalidades deportivas actuales, de ahí la importancia de conocer si dichos estiramientos tienen realmente los beneficios y resultados óptimos en la práctica deportiva habitual. Por ello, en el presente estudio habrá un grupo experimental sobre el que se realice el estiramiento estático sobre la musculatura epicondílea durante 10 segundos y otro grupo control al que se le somete una acción similar de placebo. Objetivos Analizar las diferencias existentes de diferentes parámetros de fuerza de extensión de muñeca obtenidos antes y después de realizar un estiramiento analítico pasivo de la musculatura epicondílea frente a los mismos parámetros obtenidos en un grupo control que no lo realiza y se somete a una acción similar con efecto placebo. Metodología Se realizó un estudio piloto experimental con 18 sujetos (8 mujeres y 10 hombres). Las mediciones se realizaron utilizando el sistema de dinamometría computarizada Primus-BTS. Haciendo un estudio de las distintas variables de fuerza mediante un ANOVA factorial relacionando estas variables con el sexo y el índice de masa corporal (IMC) de cada sujeto, asumiendo un p<0.05. Conclusiones Existen diferencias significativas en función del sexo para la fuerza máxima isométrica. También hay diferencias significativas en función del grupo de tratamiento, del sexo y de los valores de índice de masa corporal (IMC) para la fuerza isocinética máxima c/c a 60º/s y la fuerza isocinética máxima e/e a 90º/s.es_ES
dc.description.abstractBackground As is well known, the stretches are deeply rooted in the different current sports, therefore the importance of knowing if these stretches really have the benefits and optimal results in the usual sports practice. Therefore, in the present study there will be an experimental group on which the static stretch is performed on the epicondylar muscle for 10 seconds and another control group to which a similar action of placebo is subjected. Objectives Analyze the existing differences of different wrist extension strength parameters obtained before and after performing a passive analytical stretch of the epicondylar muscle against the same parameters obtained in a control group that does not perform it and undergoes a similar action with effect placebo. Methodology An experimental pilot study was carried out with 18 subjects (8 women and 10 men). The measurements were made using the Primus-BTS computer dynamometer system. Doing a study of the different force variables by means of a factorial ANOVA relating these variables with the sex and the body mass index (BMI) of each subject, assuming p <0.05. Conclusions There are significant differences according to sex for maximum isometric strength. There are also significant differences depending on the treatment group, sex and body mass index (BMI) values for the maximum isokinetic force c / c at 60º / s and the maximum isokinetic force e / e at 90º / s.es_ES
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoeses_ES
dc.subjectUNESCO::32 Medicina::3213 Cirugía::321311 Fisioterapiaes_ES
dc.subjectUNESCO::24 Ciencias de la vida::2406 Biofísica::240604 Biomecánicaes_ES
dc.titleAnálisis de las diferencias sobre distintos parámetros de fuerza al realizar un estiramiento sobre la musculatura extensora de muñeca del brazo dominante en sujetos sanoses_ES
dc.typeinfo:eu-repo/semantics/masterThesises_ES
dc.rights.accessRightsinfo:eu-repo/semantics/closedAccesses_ES
dc.keywordsEstiramiento, Estiramiento estático, Extensión de muñecaes_ES
dc.keywordsStretching, Static stretching, Wrist extensiones_ES
Aparece en las colecciones: H78 -Trabajos Fin de Máster

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
PFM000188.pdfProyecto Fin de Máster1,79 MBAdobe PDFVisualizar/Abrir     Request a copy
PFM000188.pdfAutorización576 kBAdobe PDFVisualizar/Abrir     Request a copy


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.