Por favor, use este identificador para citar o enlazar este ítem:
http://hdl.handle.net/11531/42468
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.advisor | Pérez Mallada, Néstor | - |
dc.contributor.author | Jimeno González, Héctor | - |
dc.contributor.other | Universidad Pontificia Comillas, Escuela Universiaria de Enfermería Y Fisioterapia | es_ES |
dc.date.accessioned | 2019-10-14T11:18:17Z | - |
dc.date.available | 2019-10-14T11:18:17Z | - |
dc.date.issued | 2019 | - |
dc.identifier.uri | http://hdl.handle.net/11531/42468 | - |
dc.description | Titulación::Postgrado::Máster Universitario en Biomecánica y Fisioterapia Deportiva | es_ES |
dc.description.abstract | Introducción: actualmente, el “Foam Roller” está siendo utilizado en el mundo del deporte como parte del calentamiento y además, en algunas disciplinas deportivas, también se utiliza para finalizar las sesiones de entrenamiento y ayudar al deportista a tener una mayor recuperación de dicha sesión. Existe una cierta controversia en los tiempos y formas de aplicación de este dispositivo, es por ello que el objetivo del presente estudio pretende analizar la efectividad de la aplicación de “Foam Roller” en el cuádriceps del futbolista previa al entrenamiento. Metodología: el presente estudio piloto cuantitativo cuasiexperimental prospectivo recoge un total de 10 sujetos, futbolistas amateurs federados por la Comunidad de Madrid durante la temporada 2018 - 2019. Dichos sujetos realizaron una medición del rango óptimo de movimiento (ROM) de flexo-extensión de rodilla, seguido de un salto CMJ, donde se recogen los valores de activación muscular y, para finalizar tres pruebas de fuerza; isométrica, isocinética a 60º/s e isocinética a 120º/s en un dinamómetro isocinético. Todas las mediciones se hicieron previa y posterior a una aplicación de “Foam Roller” en dos series de 1 minuto con un descanso de 30 segundos entre dichas series. Resultados: en la prueba de Wilcoxon donde se relaciona el pre – post de las variables dependientes, se encuentra significancia en las variables FM120 (0,022), en la variable FMI (0,005) y en la variable EMG_despegue_RF (0,037). Conclusiones: la aplicación de “Foam Roller” previa a la realización de la actividad deportiva presenta un aumento del rendimiento del atleta, aumentando los valores de fuerza y sin ninguna repercusión negativa a nivel del ROM y de la actividad electromiográfica de la musculatura del cuádriceps, tras dos minutos de rodamiento. | es_ES |
dc.description.abstract | Introduction: currently, the “Foam Roller” is being used in the world of sports as a part of the warm – up and also, in some sports disciplines, it is also used to end the training sessions and help the athlete to have a better recovery from that session. There is a certain controversy in the times and forms of application of this device. That is why the objective of this study aims to analyze the effectiveness of the application of “Foam Roller” in the quadriceps muscle of the player prior to training. Methods: the present quantitative quasi – experimental prospective pilot study includes a total of 10 subjects. These are amateur football players federated by the Community of Madrid during the 2018 – 2019 season. These subjects made a measurement of the optimal range of motion (ROM) of knee flexion and extension, followed by a CMJ jump, where muscles activations values are collected and three strength tests too; isometric, isokinetic at 60º/second and isokinetic at 120º/second with a dynamometer. All measurements were made before and after a “Foam Roller” application in two series of one minute with rest of 30 seconds between series. Results: in the Wilcoxon test the pre – post of the dependent variables are related. The significances are found in the variables FM120 (0,022), in FMI (0,005) and EMG_despegue_RF (0,037) Conclusions: the “Foam Roller” application prior to the performance of the sports activity presents an increase in the performance of the athlete, increasing the strength values and without any negative repercussions at optimal range of motion and the electromyographic activity of the quadriceps muscle, after two minutes of rolling. | es_ES |
dc.format.mimetype | application/pdf | es_ES |
dc.language.iso | es | es_ES |
dc.subject | UNESCO::32 Medicina::3213 Cirugía::321311 Fisioterapia | es_ES |
dc.title | Variaciones biomecánicas del cuádriceps, en futbolistas, tras la aplicación de masaje con “Foam Roller” | es_ES |
dc.type | info:eu-repo/semantics/masterThesis | es_ES |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | es_ES |
dc.keywords | Fuerza, Electromiografía, Foam Roller, Salto, Rango de movimiento | es_ES |
dc.keywords | Strength, Electromyography, Foam Roller, Jump, Range of motion | es_ES |
Aparece en las colecciones: | H78 -Trabajos Fin de Máster |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
PFM000191.pdf | Proyecto Fin de Máster | 1,12 MB | Adobe PDF | Visualizar/Abrir |
PFM000191.pdf | Autorización | 296,86 kB | Adobe PDF | Visualizar/Abrir Request a copy |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.