dc.description.abstractEl objetivo del proyecto presente es el diseño del sistema de climatización de un edificio de oficinas en la ciudad de Madrid, España. El documento aquí mostrado abarca todo lo relacionado con la calefacción, refrigeración y ventilación del edificio, siguiendo siempre las indicaciones del R.I.T.E. El edificio consta de una planta baja y de seis plantas sobre rasante, que se encuentran voladas en dicha planta baja. En total, el espacio a climatizar del edificio será de 3693m2. Para acondicionarlo, se diseña un sistema de climatización compuesto por un climatizador de aire primario, una enfriadora por condensación de aire, una caldera de condensación a gas, y fan coils de tipo cassette que irán instalados en los falsos techos de cada planta. Adicionalmente, se explicará en detalle el diseño de conductos y tuberías. Para la selección del sistema de climatización en los diferentes espacios, se han considerado los factores siguientes: - La eficacia de regulación: se quiere controlar la temperatura y humedad del local climatizado, para garantizar condiciones de confort deseadas. - Para cada una de las salas en las que se divide el inmueble, se han indicado unas condiciones interiores de ocupación, alumbrado, calidad de aire, ventilación, temperatura, humedad relativa; y condiciones exteriores, definidas por la ubicación y orientación del edificio. - Distinción por usos y por horarios de funcionamiento. - Agrupación de espacios con las mismas condiciones térmicas y arquitectónicas. De esta forma, se han agrupado las distintas plantas de la siguiente manera: - Planta baja - Plantas 1ª y 2ª - Plantas 3ª, 4ª y 5ª - Planta 6ª Por otro lado, cabe destacar que zonas tipo pasillos, aseos, salas de contadores y salas de almacenamiento situadas en la planta baja, no contarán con sistema de climatización. Sin embargo, los aseos sí serán tenidos en cuenta para el diseño de la extracción del edificio.es-ES
dc.description.abstractThe goal of the present project is the design of the air conditioning system of an office building in the city of Madrid, Spain. The document shown here covers everything related to the heating, cooling and ventilation of the building, always following the R.I.T.E. indications. The building consists of a ground floor and six floors above ground level, which are overhung on the first floor. In total, the space to be air-conditioned in the building will be 3693m2. To air-condition it, an air conditioning system is designed consisting of a primary air conditioner, an air condensation chiller, a gas condensing boiler, and cassette type fan coils that will be installed in the false ceilings of each floor. In addition, the duct and piping design will be explained in detail. For the selection of the air conditioning system in the different spaces, the following factors have been considered: - The regulation efficiency: it is desired to control the temperature and humidity of the air-conditioned room, in order to guarantee desired comfort conditions. - For each of the rooms into which the building is divided, interior conditions of occupancy, lighting, air quality, ventilation, temperature, relative humidity; and exterior conditions, defined by the location and orientation of the building, have been indicated. - Distinction by use and by hours of operation. - Grouping of spaces with the same thermal and architectural conditions. Thus, the different floors have been grouped as follows: - Ground floor - 1st and 2nd floors - Floors 3, 4 and 5. - 6th floor On the other hand, it should be noted that areas such as corridors, toilets, meter rooms and storage rooms located on the ground floor will not have an air conditioning system. However, the toilets will be taken into account in the design of the building's extraction system.en-GB
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoes-ESes_ES
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 United Stateses_ES
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/us/es_ES
dc.subject33 Ciencias tecnológicases_ES
dc.subject3329 Planificación regional y urbanaes_ES
dc.subject332906 Servicios sanitarioses_ES
dc.subject.otherH62-mecanica (MII-M)es_ES
dc.titleClimatización de un edificio de oficinas en Madrides_ES
dc.typeinfo:eu-repo/semantics/masterThesises_ES
dc.rights.accessRightsinfo:eu-repo/semantics/closedAccesses_ES
dc.keywordsClimatización, Oficinas, Madrid, Cargas, Conductos, Tuberíases-ES
dc.keywordsAir conditioning, Offices, Madrid, Loads, Ducts, Pipingen-GB
Aparece en las colecciones: H62-Trabajos Fin de Máster

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
Anexo I Sara Losada Vivero.pdfAutorización251,48 kBAdobe PDFVista previa
Visualizar/Abrir
TFM - Losada Vivero Sara.pdfTrabajo Fin de Máster11,16 MBAdobe PDFVista previa
Visualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.