Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/11531/58143
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorBlanco Méndez, Ricardoes-Es
dc.contributor.authorde Santos Yubero, Héctores-ES
dc.contributor.authorSanz Bobi, Miguel Ángeles-ES
dc.contributor.other, Escuela Universitaria de Enfermería y Fisioterapiaes_ES
dc.date.accessioned2021-07-15T18:11:41Z-
dc.date.available2021-07-15T18:11:41Z-
dc.date.issued2022-06-01es_ES
dc.identifier.issn0885-8977es_ES
dc.identifier.otherE000005032es_ES
dc.identifier.urihttps:doi.org10.1109TPWRD.2021.3103894es_ES
dc.descriptionArtículos en revistases_ES
dc.description.abstractes-ES
dc.description.abstractToughened glass insulators installed in overhead lines play a key role in maintaining the reliability and safety of power systems. The singular properties of toughened glass make this material particularly suitable for this application on account of its excellent dielectric properties, high mechanical strength and easiness of inspection. If the glass was damaged, it would shatter completely leaving the remaining part of the insulator, called stub, still providing mechanical connection and being easily detectable from the ground by a visual inspection. In this paper, the mechanical reliability of toughened glass insulators is investigated through the analyses of experimental data obtained from laboratory tests. First, the mechanical strength of the toughened glass in insulators and the relationship between its failing load and the geometry of the insulator are investigated by means of a novel analytical approach. Afterwards, the risk of mechanical failure of glass insulators and stubs, with the shell broken off, is analysed. The results show the mechanical reliability of glass insulators for different string configurations and for large and complex systems deployed in 220 kV and 400 kV transmission lines. Finally, the effect of the shattering rate on the reliability is studied under the most adverse conditions.en-GB
dc.format.mimetypeapplication/octet-streames_ES
dc.language.isoen-GBes_ES
dc.sourceRevista: IEEE Transactions on Power Delivery, Periodo: 1, Volumen: online, Número: 3, Página inicial: 2083, Página final: 2089es_ES
dc.subject.otherInstituto de Investigación Tecnológica (IIT)es_ES
dc.titleNovel approaches to assess the mechanical reliability of toughened glass insulators used in transmission lineses_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.description.versioninfo:eu-repo/semantics/publishedVersiones_ES
dc.rights.holderes_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.keywordses-ES
dc.keywordsInsulators , mechanical reliability , shattering , toughened glass , transmission linesen-GB
asignatura.cursoacademico2022-2023es_ES
asignatura.periodoes_ES
asignatura.creditos3.0es_ES
asignatura.tipoObligatoria (Grado)es_ES
Aparece en las colecciones: KFS-Guías Docentes

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
Guía Docente.pdf178,04 kBAdobe PDFVista previa
Visualizar/Abrir
IIT-21-120R_preview2,89 kBUnknownVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.