Por favor, use este identificador para citar o enlazar este ítem:
http://hdl.handle.net/11531/68160
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.advisor | Fernandes Ribeiro, Ana Sofía | - |
dc.contributor.author | Bayo San Juan, Mikel | - |
dc.contributor.other | Universidad Pontificia Comillas, Escuela Universiaria de Enfermería Y Fisioterapia | es_ES |
dc.date.accessioned | 2022-05-13T11:01:23Z | - |
dc.date.available | 2022-05-13T11:01:23Z | - |
dc.date.issued | 2021 | - |
dc.identifier.uri | http://hdl.handle.net/11531/68160 | - |
dc.description | Titulación::Postgrado::Máster Universitario en Biomecánica y Fisioterapia Deportiva | es_ES |
dc.description.abstract | Objetivo: Analizar los cambios sobre la velocidad de ejecución de un Dead Lift, así como los cambios sobre la señal EMGs de los músculos extensores de cadera, tras una manipulación global de pelvis bilateral. Metodologia: Estudio cuasiexperimental. Se reclutaron doce sujetos, con una edad comprendida entre los 20 y los 35 años, que realizaron ejercicio de musculación gimnasio, calistenia o crosfit, sin operaciones a nivel del raquis o ilíacos y que supiesen ejecutar la técnica del DeadLift. Se realizó el ejercicio del DeadLift, monitorizado con un EMGs en los músculos bíceps femoral, semitendinoso y glúteo mayor, también se monitorizó mediante un Encoder, bajo la barra de peso y atado en el centro de esta. La barra utilizada fué de 10kg, y el peso que se le añadió, fué la mitad del RM del paciente. La intervención fue una técnica de manipulación global de pelvis, después se reevaluó con el mismo ejercicio. Las variables que se midieron, fueron: Pico de actividad muscular (Hz) mediante el EMGs; Velocidad de ejecución de movimiento (m/s) mediante el Encoder. Resultados: Tras realizar las mediciones, se analizaron estadísticamente los resultados a través del IBM SPSS (IBM Corporation, New York, USA), versión 24.0® para Windows. Se hizo una descripción de las variables y la prueba de normalidad de Shapiro-Wilks (n<30), dando como resultado una distribución normal. A partir de aquí se realizó la prueba estadística T-Student para muestras relacionadas donde todos los valores p de significancia, fueron superiores a 0,05 (0,460; 0,890; 0,724; 0,185; 0,991; 0,567; 0,192). La manipulación global de la pelvis, no tuvo efectos positivos a nivel de velocidad de ejecución ni de la actividad muscular. Conclusión: No se han observado cambios sobre la velocidad de ejecución de un Dead Lift ni en la señal EMGs de los músculos extensores de cadera, tras una manipulación global de pelvis bilateral. Por ello, se sugiere que se aumente la muestra de sujetos y se alcance la N estimada en el cálculo muestral. | es_ES |
dc.description.abstract | Objective: To analyze variations in the Deadlift execution velocity, as well as in the EMGs signal of the hip extensor muscles, after manipulating the global pelvic bilaterally. Methodology: Quasi-experimental study. Twelve subjects between the ages of 20 and 35 were recruited, who knew how to execute the DeadLift operation, and performed callisthenics, CrossFit or gym muscle exercises, without operations at the spine or iliac level. The DeadLift exercise was executed by using an EMGs to motorize the biceps femoris, semitendinosus, and gluteus maximus muscles, It was also monitored by an Encoder, tied below in the centre of it. The weight of the barbell used was 10kg plus half of the patient’s RM. The intervention consisted of a global pelvic manipulation technique, then reassessed with the same exercise. The variables measured were: Peak muscle activity (Hz) by EMGs; Movement execution speed (m / s) by the Encoder. Results: After measuring, results were statistically analyzed through the IBM SPSS (IBM Corporation, New York, USA) Windows 24.0 version. A description of the variable and a Shapiro-Wilks (n<30) normality test were carried out, resulting in a normal distribution. Then, a T-Student statistic test was made for related samples where all significance p values were greater than 0.05 (0,460; 0,890;0,724; 0,185; 0,991; 0,567; 0,192). The global manipulation of the pelvis had no positive effects on the level of execution speed or muscular activity. Conclusion: No variations were shown in the deadlift execution speed or in the EMG signal of the hip extensor muscles after bilateral global pelvic manipulation. For this reason, an increase in the sample of subjects is recommended, so the N estimated in the sample calculus can be reached. | es_ES |
dc.format.mimetype | application/pdf | es_ES |
dc.language.iso | es | es_ES |
dc.rights | Attribution-NonCommercial-NoDerivs 3.0 United States | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/us/ | * |
dc.subject | UNESCO::32 Medicina::3213 Cirugía::321311 Fisioterapia | es_ES |
dc.subject | UNESCO::24 Ciencias de la vida::2406 Biofísica::240604 Biomecánica | es_ES |
dc.title | Análisis de la actividad eléctrica y velocidad de ejecución durante un DeadLift tras la aplicación de una manipulación global de pelvis | es_ES |
dc.type | info:eu-repo/semantics/masterThesis | es_ES |
dc.rights.accessRights | info:eu-repo/semantics/closedAccess | es_ES |
dc.keywords | Peso muerto, Manipulación global de pelvis, Emgs, Encoder | es_ES |
dc.keywords | DeadLift, Global pelvis manipulation, EMGs, Encoder | es_ES |
Aparece en las colecciones: | H78 -Trabajos Fin de Máster |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
PFM000222.pdf | Proyecto Fin de Máster | 1,78 MB | Adobe PDF | Visualizar/Abrir Request a copy |
PFM000222 Autorizacion.pdf | Autorización | 113,32 kB | Adobe PDF | Visualizar/Abrir Request a copy |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.