dc.description.abstract | Este proyecto tiene como objetivo el diseño de un sistema de climatización para un edificio de oficinas situado en Badajoz. Durante su elaboración, se ha seguido la normativa actual en materia de construcción para garantizar su habitabilidad, seguridad y eficiencia energética. Para ello, el primer paso es definir las características constructivas del edificio, incluyendo sus dimensiones y la división de sus plantas, áreas y oficinas. Después se elegirán las plantas a climatizar dividiendo las mismas en módulos para asegurar una efectiva climatización. Posteriormente, se deben establecer las hipótesis de diseño, teniendo en cuenta las condiciones internas y externas, como los niveles de ocupación, la iluminación, las cargas de los equipos eléctricos y los coeficientes de seguridad y transmisión. El siguiente paso es calcular las cargas para las estaciones de verano e invierno, considerando las condiciones más desfavorables en ambos casos, concretamente los meses más calurosos y fríos de la ciudad de Badajoz. Con los datos obtenidos en el cálculo de cargas se procederá a la selección de los equipos en concreto los fan-coils, caldera, enfriadora y climatizador. Al haber seleccionado los fan-coils y saber cuántos se tendrán por planta se realizará el diseño de la instalación de las tuberías. Se calculará las pérdidas que tienen para poder seleccionar unas bombas que garanticen el correcto funcionamiento de la instalación. Una vez realizados estos cálculos, se obtendrán los caudales de ventilación y retorno según la normativa RITE. Por último, se diseñarán las redes de conductos y se presentarán en planos, juntos con la red de tuberías haciendo uso de AutoCAD, tras lo cual se elaborarán las especificaciones de los equipos y se planificará el presupuesto. | es-ES |
dc.description.abstract | The objective of this project is the design of an air conditioning system for an office building located in Badajoz. During its elaboration, the current building regulations have been followed in order to guarantee its habitability, safety and energy efficiency. The first step was to define the building's constructive characteristics, including its dimensions and the division of its floors, areas and offices. Then, the floors to be air-conditioned will be chosen, dividing them into modules to ensure effective air-conditioning. Subsequently, the design assumptions must be established, taking into account internal and external conditions, such as occupancy levels, lighting, electrical equipment loads, and safety and transmission coefficients. The next step is to calculate the loads for the summer and winter seasons, considering the most unfavorable conditions in both cases, specifically the hottest and coldest months in the city of Badajoz. With the data obtained in the load calculation, we will proceed to the selection of the equipment, specifically the fan-coils, boiler, chiller and air conditioner. Once the fan-coils have been selected and the number of fan-coils per floor is known, the design of the piping installation will be carried out. The losses they have will be calculated in order to select pumps that guarantee the correct operation of the installation. Once these calculations have been made, the ventilation and return flow rates will be obtained according to RITE regulations. Finally, the duct networks will be designed and presented in drawings, together with the piping network using AutoCAD, after which the equipment specifications will be drawn up and the budget will be planned. | en-GB |
dc.format.mimetype | application/pdf | es_ES |
dc.language.iso | es-ES | es_ES |
dc.rights | Attribution-NonCommercial-NoDerivs 3.0 United States | es_ES |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/us/ | es_ES |
dc.subject | 33 Ciencias tecnológicas | es_ES |
dc.subject | 3313 Tecnología e ingeniería mecánica | es_ES |
dc.subject | 331326 Equipo de refrigeración | es_ES |
dc.subject.other | KTI-mecanica (GITI-M) | es_ES |
dc.title | Climatización de un edificio de oficinas en Badajoz | es_ES |
dc.type | info:eu-repo/semantics/bachelorThesis | es_ES |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | es_ES |
dc.keywords | es-ES | |
dc.keywords | en-GB | |
Aparece en las colecciones: | KTI-Trabajos Fin de Grado |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
TFG-Recio Olmo Daniel.pdf | Trabajo Fin de Grado | 12,17 MB | Adobe PDF | Visualizar/Abrir |
ANEXO I DANIEL RECIO OLMO.pdf | Autorización | 722,74 kB | Adobe PDF | Visualizar/Abrir Request a copy |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.