Título : Carbon neutral Cornell : environmental sustainability improvements at the Llenroc house
Autor : Vanek, Francis M.
García Prieto, Santiago Blas
Universidad Pontificia Comillas, Escuela Técnica Superior de Ingeniería (ICAI)
Palabras clave : 33 Ciencias tecnológicas;3305 Tecnología de la construcción;330522 Metrología de la edificación
Fecha de publicación : 2023
Resumen : El trabajo Carbon Neutral Cornell: environmental sustainability improvements at the Llenroc house es un estudio de viabilidad realizado con el objetivo de proporcionar a la fraternidad Delta Phi de Cornell un plan para renovar energéticamente su casa principal, llamada Llenroc. Actualmente, el edificio alberga a 19 alumnos de Cornell y pretende sustituir sus tecnologías actuales por otras respetuosas con el medio ambiente. En este documento se explicará la decisión dada a la organización. Dicha solución consiste en sustituir la caldera de gas de Llenroc por una bomba de calor geotérmica de 80 kW que calentará y enfriará la casa cuando sea necesario, así como un sistema de paneles solares de 101 kW de capacidad que suministrará electricidad limpia a Llenroc. El coste inicial total de este proyecto sería de 298.511 dólares. Aunque pueda parecer caro, el coste de no realizar estas reformas sería más elevado. Esta solución se presentó a la junta directiva de Delta Phi en mayo de 2023 en Ithaca, Nueva York.
The Carbon Neutral Cornell: environmental sustainability improvements at the Llenroc house is a feasibility study conducted with the objective of providing Cornell’s Delta Phi Fraternity with a plan to renew energetically their main house, named Llenroc. The building currently hosts 19 Cornell students and is seeking to replace its current technologies with others that are eco-friendly. Therefore, this document will explain the decision given to the organization. This solution consists in replacing Llenroc’s gas boiler with an 80 kW geothermal heat pump that will heat and cool the house when needed and a 101 kW solar array that will provide Llenroc with clean electricity. The total initial cost of this project would be $298,511. Although it might seem expensive, it was found that the cost of not undergoing these renovations would be more expensive. This solution was presented to the board of directors of Delta Phi.
Descripción : Grado en Ingeniería en Tecnologías Industriales y Grado en Administración y Dirección de Empresas
URI : http://hdl.handle.net/11531/77265
Aparece en las colecciones: KTI-Trabajos Fin de Grado

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
TFG_Garcia_Prieto_SantiagoBlas.pdfTrabajo Fin de Grado1,91 MBAdobe PDFVisualizar/Abrir
GarciaPrietoSantiago_ConfirmacionAutoriaTFG.pdfAutorización105,91 kBAdobe PDFVisualizar/Abrir     Request a copy


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.