Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/11531/78615
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorSantacruz Peláez, Davides-ES
dc.contributor.advisorTroncia, Matteoes-ES
dc.contributor.authorMorales Montoya, Beatrizes-ES
dc.contributor.otherUniversidad Pontificia Comillas, Escuela Técnica Superior de Ingeniería (ICAI)es_ES
dc.date.accessioned2023-06-06T11:43:42Z-
dc.date.available2023-06-06T11:43:42Z-
dc.date.issued2023es_ES
dc.identifier.urihttp://hdl.handle.net/11531/78615es_ES
dc.descriptionMáster Universitario en Ingeniería Industrial + Máster in Smart Gridses_ES
dc.description.abstractEste documento es un trabajo fin de máster, que ha sido realizado en colaboración con i-DE, Redes Eléctricas Inteligentes, la empresa de distribución el del grupo Iberdrola. Consiste en un análisis estadístico de la información de los sistemas de ensayo Dynamic Line Rating (DLR) ya instalados en algunas líneas como proyecto piloto. El DLR permite optimizar la capacidad de las líneas existentes en función de las condiciones meteorológicas, y el objetivo principal de su implantación en Iberdrola es mejorar la flexibilidad de la red mediante su reconfiguración. Este estudio analiza y evalúa diferentes tecnologías DLR, el impacto de las variables meteorológicas y otros parámetros como la altitud, diferentes estándares para el cálculo del rating, equipos DLR, retos con su despliegue y enfoques futuros. Todo ello se realiza con el fin último de definir un plan para el despliegue de esta tecnología para 2030 el grupo Iberdrola.es-ES
dc.description.abstractThis document is a final master thesis, that has been carried out in collaboration with i-DE, Redes Eléctricas Inteligentes, the Distribution System Operator of Iberdrola’s group. It consists of a statistical analysis of the information from the Dynamic Line Rating (DLR) testing systems already installed in some lines as a pilot project. DLR enables the optimization of existing line capacity based on weather conditions, and the primary objective of its implementation at Iberdrola is to enhance grid flexibility through reconfiguration. This study analyses and evaluates different DLR technologies, the impact of the weather variables and other parameters such as altitude, different standards for the calculation of the rating, DLR equipment, challenges with its deployment and future approaches. It is done with the ultimate purpose of defining recommendations for the 2030 deployment of this technology for Iberdrola group.en-GB
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoes-ESes_ES
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 United Stateses_ES
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/us/es_ES
dc.subject.otherM8Ees_ES
dc.titleAnalysis of information from the installed Dynamic Line Rating (DLR) systems, to definea deployment plan up to 2030es_ES
dc.typeinfo:eu-repo/semantics/masterThesises_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.keywordsDynamic Line Rating, Redes inteligentes, flexibilidad, capacidad.es-ES
dc.keywordsDynamic Line Rating, Smart Grids, flexibility, capacity.en-GB
Aparece en las colecciones: M8E - Trabajos Fin de Máster

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
TFM - Morales Montoya, Beatriz.pdfTrabajo Fin de Máster658,88 kBAdobe PDFVista previa
Visualizar/Abrir
Anexo I - firmado.pdfAutorización146,61 kBAdobe PDFVisualizar/Abrir     Request a copy


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.