Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/11531/82946
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorPortillo García, Julio Rafaeles-ES
dc.contributor.authorGarcía San Miguel, Belénes-ES
dc.contributor.otherUniversidad Pontificia Comillas, Escuela Técnica Superior de Ingeniería (ICAI)es_ES
dc.date.accessioned2023-09-12T17:55:57Z-
dc.date.available2023-09-12T17:55:57Z-
dc.date.issued2024es_ES
dc.identifier.urihttp://hdl.handle.net/11531/82946es_ES
dc.descriptionMáster Universitario en Ingeniería Industriales_ES
dc.description.abstractLa necesidad de reducir emisiones de carbono ha impulsado el uso de plantas eólicas marinas, pero su rápido crecimiento y los costos inciertos plantean desafíos. Este proyecto estudia técnica y económicamente la conexión de una planta eólica offshore en el área de AC, desarrollando una herramienta para calcular CAPEX y OPEX. La investigación aborda el estado actual de la tecnología, considerando diseños eléctricos y mecánicos, métodos de transporte de energía, y desafíos sostenibles. Utilizando un caso de estudio en el Mar del Norte, se diseñó la red eléctrica de un parque con 50 turbinas, incluyendo cableado y subestaciones, y se creó una herramienta automatizada para el diseño y análisis económico. Además, se calculó y comparó la pérdida de energía en los cables, estimada en 3.7% a 66 kV. Los resultados proporcionan una base sólida para evaluar la viabilidad y planificación de plantas eólicas marinas, optimizando costos y eficiencia. Este proyecto contribuye al avance de soluciones energéticas sostenibles y amplía el conocimiento técnico y económico en el campo de la energía eólica offshore.es-ES
dc.description.abstractThe need to reduce carbon emissions has driven the use of offshore wind farms, but their rapid growth and uncertain costs pose challenges. This project technically and economically studies the connection of an offshore wind farm in the AC area, developing a tool to calculate CAPEX and OPEX. The research addresses the current state of technology, considering electrical and mechanical designs, energy transportation methods, and sustainability challenges. Using a case study in the North Sea, the electrical network of a park with 50 turbines was designed, including cabling and substations, and an automated tool for design and economic analysis was created. Additionally, energy loss in the cables was calculated and compared, estimated at 3.7% at 66 kV. The results provide a solid foundation for assessing the feasibility and planning of offshore wind farms, optimizing costs and efficiency. This project contributes to the advancement of sustainable energy solutions and expands technical and economic knowledge in the field of offshore wind energy.en-GB
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoes-ESes_ES
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 United Stateses_ES
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/us/es_ES
dc.subject.otherH62-electrotecnica (MII-E)es_ES
dc.titleEstudio de conexión de planta eólica offshore en ACes_ES
dc.typeinfo:eu-repo/semantics/masterThesises_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.keywordsCoste de inversión, coste de operación, coste de mantenimiento, subestación, transformador, cableado.es-ES
dc.keywordsInvestment cost, operation cost, maintenance cost, substation, transformer, wiring.en-GB
Aparece en las colecciones: H62-Trabajos Fin de Máster

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
TFM_Garcia San Miguel, Belen.pdfTrabajo Fin de Máster2,24 MBAdobe PDFVista previa
Visualizar/Abrir
AnexoI_PGJ_BG.pdfAutorización141,5 kBAdobe PDFVista previa
Visualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.