Por favor, use este identificador para citar o enlazar este ítem:
http://hdl.handle.net/11531/83259
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.advisor | Norverto Moriñigo, Juan | es-ES |
dc.contributor.advisor | Sanz Fernández, Iñigo | es-ES |
dc.contributor.author | Frías Ballester, Enrique Patricio | es-ES |
dc.contributor.other | Universidad Pontificia Comillas, Escuela Técnica Superior de Ingeniería (ICAI) | es_ES |
dc.date.accessioned | 2023-09-19T06:43:34Z | - |
dc.date.available | 2023-09-19T06:43:34Z | - |
dc.date.issued | 2024 | es_ES |
dc.identifier.uri | http://hdl.handle.net/11531/83259 | es_ES |
dc.description | Máster Universitario en Ingeniería Industrial + Máster en Industria Conectada / in Smart Industry | es_ES |
dc.description.abstract | Este proyecto ha consistido, inicialmente en una exploración de las tecnologías existentes del mercado CPAP actual, explorando e identificando sus puntos débiles. Se ha encontrado que este mercado tiene un precio elevado, por lo que hay un porcentaje importante de la población que no es capaz de tratar trastornos del sueño mediante el tratamiento CPAP, que es actualmente el más efectivo contra los trastornos del sueño más habituales, como la apnea del sueño. Una vez identificado un nicho potencial, se ha diseñado un prototipo específicamente con el requisito de mantener un coste inferior al del mercado actual. Para ello, se han identificado los componentes clave, con los cuales se puede conseguir el tratamiento básico, y los componentes prescindibles, que no se han añadido en el prototipo ya que aportan coste sin presentar ventajas para el funcionamiento esencial del prototipo CPAP. Además de seleccionar los componentes, se ha llevado a cabo el diseño de la carcasa principal, en la que irán almacenados estos. Por último, se ha desarrollado también un algoritmo de control que permite auto ajustar la presión proporcionada por el dispositivo CPAP en función de la presión deseada por el usuario. Por último, tras diseñar y producir el prototipo completamente, se ha pasado a desarrollar y analizar el modelo de negocio que se desea implantar. Tras realizar análisis del mercado y competidores, se ha podido proyectar las ventas esperadas en los próximos años, así como los costes, obteniendo unos resultados financieros, que han confirmado que a largo plazo, el modelo es viable y atractivo. | es-ES |
dc.description.abstract | This project initially involved exploring the existing technologies in the current CPAP market, identifying their weaknesses. It was found that this market is priced high, meaning a significant portion of the population cannot afford to treat sleep disorders with CPAP therapy, which is currently the most effective against common sleep disorders such as sleep apnea. After identifying a potential niche, a prototype was designed specifically to maintain a cost lower than the current market rate. To achieve this, key components were identified that can provide basic treatment, and dispensable components that were not included in the prototype as they add cost without providing benefits for the essential operation of the CPAP prototype. In addition to selecting components, the main housing design was carried out, where these will be stored. Lastly, a control algorithm was also developed that allows the CPAP device to auto-adjust the pressure based on the user's desired pressure. Finally, after fully designing and producing the prototype, development and analysis of the business model intended for implementation proceeded. After conducting market and competitor analysis, expected sales over the next few years and costs were projected, yielding financial results that have confirmed that the model is viable and attractive in the long term. | en-GB |
dc.format.mimetype | application/pdf | es_ES |
dc.language.iso | es-ES | es_ES |
dc.rights | Attribution-NonCommercial-NoDerivs 3.0 United States | es_ES |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/us/ | es_ES |
dc.subject.other | H62-mecanica (MII-M) | es_ES |
dc.title | Diseño y desarrollo de máquina low cost de respiración nocturna asistida (apnea antironquidos) CPAP | es_ES |
dc.type | info:eu-repo/semantics/masterThesis | es_ES |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | es_ES |
dc.keywords | CPAP, low-cost, prototipo, modelo de negocio | es-ES |
dc.keywords | CPAP, low-cost, prototype, business model | en-GB |
Aparece en las colecciones: | H62-Trabajos Fin de Máster |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
TFM Frias Ballester Enrique.pdf | Trabajo Fin de Máster | 6,15 MB | Adobe PDF | Visualizar/Abrir |
Anexo I Frias Ballester Enrique.pdf | Autorización | 33,28 kB | Adobe PDF | Visualizar/Abrir |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.