Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/11531/83456
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorMendizábal, Eduardoes-ES
dc.contributor.authorEntrena García, Marioes-ES
dc.contributor.otherUniversidad Pontificia Comillas, Escuela Técnica Superior de Ingeniería (ICAI)es_ES
dc.date.accessioned2023-09-27T06:20:55Z-
dc.date.available2023-09-27T06:20:55Z-
dc.date.issued2024es_ES
dc.identifier.urihttp://hdl.handle.net/11531/83456es_ES
dc.descriptionMáster Universitario en Ingeniería Industriales_ES
dc.description.abstractEl presente proyecto tiene como objetivo principal el diseño de las instalaciones eléctricas y de protección contra incendios para una nave logística. El proyecto comienza comprendiendo las necesidades del cliente, considerando factores como la capacidad de almacenamiento o las características específicas del producto almacenado (botellas de vidrio). A continuación, se definen los objetivos concretos del proyecto, los cuales se centran en garantizar la seguridad de las personas y las instalaciones, cumpliendo en todo momento con la normativa vigente. El punto de partida del sistema de protección contra incendios es el cálculo de la carga de fuego asociada al material que se prevé almacenar. Tras la obtención del nivel de riesgo intrínseco correspondiente a la instalación, se seleccionan los equipos de protección necesarios, definiendo del mismo modo los recorridos de evacuación y los requisitos del alumbrado de emergencia. Por otro lado, la instalación eléctrica debe cubrir las necesidades energéticas del cliente. Tras la previsión y reparto de cargas, se procede al diseño de la arquitectura de red completando la división y colocación de los cuadros secundarios. También se deben dimensionar los conductores y las protecciones del sistema, garantizando en todo momento una instalación segura. La documentación del proyecto está compuesta por los siguientes documentos: • Memoria: Descripción detallada de las soluciones adoptadas, justificación de los cálculos y cumplimiento de la normativa. • Planos: Representación gráfica de la instalación eléctrica y protección contra incendios. • Pliego de Condiciones: Especificaciones técnicas del proyecto. • Estudio Básico de Seguridad y Salud: Evaluación de los riesgos laborales y medidas preventivas. • Mediciones y Presupuesto: Estimación del coste del proyecto. • Estudio de Impacto Ambiental: Evaluación de los impactos ambientales. En conclusión, este proyecto proporciona una solución integral y segura para las instalaciones eléctricas y de protección contra incendios de la nave logística, garantizando el cumplimiento de los requisitos legales y técnicos.es-ES
dc.description.abstractThe primary objective of this project is to design the electrical and fire protection systems for a logistics warehouse. The project commences by understanding the client's specific needs, considering factors such as storage capacity and the characteristics of the stored product (glass bottles). Subsequently, specific project objectives are defined, focusing on ensuring the safety of personnel and the facility, while strictly adhering to all applicable regulations. The design of the fire protection system begins with calculating the fire load associated with the stored material. Once the intrinsic risk level of the installation is determined, necessary protection equipment is selected. Evacuation routes and emergency lighting requirements are also defined. On the other hand, the electrical installation must meet the client's energy requirements. Following the forecasting and distribution of loads, the network architecture is designed, completing the division and placement of sub-panels. Conductors and system protections must also be sized, ensuring a safe installation at all times. Project documentation comprises the following: • Technical Report: A detailed description of the adopted solutions, justification of calculations, and compliance with regulations. • Drawings: Graphical representation of the electrical installation and fire protection systems. • Technical Specifications: Technical specifications of the project. • Basic Safety and Health Study: Evaluation of occupational risks and preventive measures. • Measurements and Budget: Estimation of the project cost. • Environmental Impact Study: Assessment of environmental impacts. In conclusion, this project provides a comprehensive and safe solution for the electrical and fire protection systems of the logistics warehouse, ensuring compliance with legal and technical requirements.en-GB
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoes-ESes_ES
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 United Stateses_ES
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/us/es_ES
dc.subject.otherH62-mecanica (MII-M)es_ES
dc.titleDiseño de la instalación eléctrica, climatización y sistema antiincendios de una naveindustrial situada en San Asensio, La Riojaes_ES
dc.typeinfo:eu-repo/semantics/masterThesises_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.keywordsInstalación, Incendios, Eléctrica, Logística, Proteccioneses-ES
dc.keywordsInstallation, Fire, Electrical, Logistics, Protectionen-GB
Aparece en las colecciones: H62-Trabajos Fin de Máster

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
TFM - Entrena Garcia, Mario.pdfTrabajo Fin de Máster4,64 MBAdobe PDFVisualizar/Abrir     Request a copy
Anexo I - Entrena Garcia, Mario.pdfAutorización99,96 kBAdobe PDFVisualizar/Abrir     Request a copy


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.