dc.description | Máster Universitario en Ingeniería Industrial | es_ES |
dc.description.abstract | El edificio de estudio se encuentra en la provincia de La Coruña, España. Se trata de un bloque de oficinas, el cual consta de dos plantas principales, una planta baja y un semisótano. El proyecto a realizar va a centrarse solamente en el estudio del sistema de climatización de la primera planta para así no hacer redundante el cálculo del sistema para las diferentes plantas. Esta primera planta tiene un área de 1200 m^2 (incluyendo el patio interior) dedicada en su mayor parte a salas de reuniones y oficinas, aunque dentro de esta planta y también incluido en el estudio se encuentran una cocina y un comedor para los trabajadores, así como un vestíbulo principal, el área total estudiada para esta serie de módulos será de 625 m^2. Para la correcta climatización de la planta se dividirá la planta en diferentes módulos, como se ha comentado anteriormente, ya que no se tendrá el mismo sistema de climatización para toda la planta en conjunto. Tanto el vestíbulo como el comedor estarán diseñados con un climatizador de caudal constante (AC1). Ligado al sistema del comedor se encontrará el de la cocina, módulo en el que se deberá tener debidamente en cuenta la extracción de aire (AC2). Por último, el sistema de las oficinas y despachos funcionarán a través de fancoils a través de un climatizador de aire primario (AP1). Por otra parte, cabe destacar al tratarse de un proyecto de climatización de un bloque de oficinas, la importancia y necesidad del bienestar de los trabajador y personas que frecuenten el edificio. Se tendrán en cuenta a la hora de realizar el proyecto estos factores humanos, así como la realización de los sistemas de climatización de la manera más eficiente y sostenible posible. | es-ES |
dc.description.abstract | The study building is located in the province of La Coruña, Spain. It is an office block, which consists of two main floors, a ground floor and a semi-basement. The project will only focus on the study of the air conditioning system of the first floor so as not to make the calculation of the system for the different floors redundant. This first floor has an area of 1200 m^2 (including the inner courtyard) dedicated mostly to meeting rooms and offices, although within this floor and also included in the study are a kitchen and a canteen for workers, as well as a main lobby, the total area studied for this series of modules will be 625 m^2. For the correct air-conditioning of the plant, the plant will be divided into different modules, as mentioned above, as the same air-conditioning system will not be used for the entire plant as a whole. Both the lobby and the dining room shall be designed with a constant flow air-conditioning unit (AC1). Linked to the dining room system will be the kitchen system, a module in which air extraction (AC2) must be duly taken into account. Finally, the system in the offices and offices will operate by means of fan coils through a primary air conditioning unit (AP1). On the other hand, as this is an air-conditioning project for an office block, the importance and necessity of the well-being of the workers and people who frequent the building should be emphasised. These human factors will be taken into account when carrying out the project, as well as the implementation of the air conditioning systems in the most efficient and sustainable way possible. | en-GB |
dc.format.mimetype | application/pdf | es_ES |
dc.language.iso | es-ES | es_ES |
dc.rights | Attribution-NonCommercial-NoDerivs 3.0 United States | es_ES |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/us/ | es_ES |
dc.subject.other | H62-mecanica (MII-M) | es_ES |
dc.title | Climatización de un edificio de oficinas en La Coruña | es_ES |
dc.type | info:eu-repo/semantics/masterThesis | es_ES |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | es_ES |
dc.keywords | Climatización Fancoil Conductos Tuberías Cargas | es-ES |
dc.keywords | Air conditioning Fancoil Ducting Loads | en-GB |
Aparece en las colecciones: | H62-Trabajos Fin de Máster |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
TFM-Gomez-Pablos Fernandez del Campo,Carmen.pdf | Trabajo Fin de Máster | 8,23 MB | Adobe PDF | Visualizar/Abrir |
ANEXO I Carmen Gomez - Pablos.pdf | Autorización | 53,48 kB | Adobe PDF | Visualizar/Abrir |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.