Por favor, use este identificador para citar o enlazar este ítem:
http://hdl.handle.net/11531/86298
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.advisor | Martín Serrano, Javier | es-ES |
dc.contributor.author | Vidal López, Jaime | es-ES |
dc.contributor.other | Universidad Pontificia Comillas, Escuela Técnica Superior de Ingeniería (ICAI) | es_ES |
dc.date.accessioned | 2024-01-17T10:57:49Z | - |
dc.date.available | 2024-01-17T10:57:49Z | - |
dc.date.issued | 2024 | es_ES |
dc.identifier.uri | http://hdl.handle.net/11531/86298 | es_ES |
dc.description | Grado en Ingeniería en Tecnologías Industriales | es_ES |
dc.description.abstract | Este proyecto propone e instala un sistema de climatización para un aeropuerto en Murcia, cumpliendo con la normativa vigente. El edificio tiene cuatro plantas y se climatizarán las áreas de facturación, llegadas y salidas, con equipos ubicados en la cubierta. 1. **Cálculo de cargas:** Se estudió la geometría y orientación del edificio para calcular las cargas térmicas en verano e invierno, considerando la normativa RITE que establece 24ºC y 50% de humedad relativa. 2. **Diseño de climatizadores:** Se dimensionaron seis climatizadores de caudal constante (dos por zona), determinando el caudal y la temperatura de impulsión. 3. **Dimensionamiento de conductos y tuberías:** Se calcularon los conductos de impulsión y retorno, y las tuberías para transportar agua fría o caliente, garantizando una velocidad no superior a 7 m/s y una pérdida de carga < 0.12 mm de c.d.a./m. 4. **Planos y documentación:** Se elaboraron los planos de los circuitos, un pliego de condiciones y un presupuesto. El proyecto se alinea con los Objetivos de Desarrollo Sostenible: Industria, Innovación e Infraestructura; Acción por el Clima; Alianzas para Lograr los Objetivos; y Energía Asequible. | es-ES |
dc.description.abstract | This project proposes and installs a climate control system for an airport in Murcia, complying with current regulations. The building has four floors, and the check-in, arrivals, and departures areas will be climate-controlled, with equipment located on the roof. - **Load Calculation:** The building's geometry and orientation were studied to calculate thermal loads in summer and winter, considering the RITE regulation, which establishes 24ºC and 50% relative humidity. - **Design of Climate Control Units:** Six constant flow climate control units were sized (two per zone), determining the supply flow and temperature. - **Sizing of Ducts and Pipes:** The supply and return ducts were calculated, and the pipes for transporting cold or hot water, ensuring a speed not exceeding 7 m/s and a pressure drop < 0.12 mm of c.d.a./m. - **Plans and Documentation:** Circuit plans, a specification document, and a budget were prepared. The project aligns with the Sustainable Development Goals: Industry, Innovation, and Infrastructure; Climate Action; Partnerships for the Goals; and Affordable Energy. | en-GB |
dc.format.mimetype | application/pdf | es_ES |
dc.language.iso | es-ES | es_ES |
dc.rights | Attribution-NonCommercial-NoDerivs 3.0 United States | es_ES |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/us/ | es_ES |
dc.subject.other | KTI-mecanica (GITI-M) | es_ES |
dc.title | Climatización de un aeropuerto localizado en Burgos | es_ES |
dc.type | info:eu-repo/semantics/bachelorThesis | es_ES |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | es_ES |
dc.keywords | CLIMATIZACIÓN AEROPUERTO MURCIA | es-ES |
dc.keywords | MURCIA AIRPORT CLIMATE CONTROL | en-GB |
Aparece en las colecciones: | TFG, TFM (temporales) |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
TFG_VIDAL_LOPEZ_JAIME.pdf | Trabajo Fin de Grado | 4,39 MB | Adobe PDF | Visualizar/Abrir |
ANEXO I Jaime Vidal Lopez.pdf | Autorización | 69,23 kB | Adobe PDF | Visualizar/Abrir |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.