dc.description.abstractEste proyecto evalúa la efectividad de los sistemas de control de humo en almacenes logísticos para mitigar los riesgos de incendios. Se analizan tecnologías actuales y su integración con otras medidas de protección, enfatizando la importancia de un diseño adecuado que incluya la optimización de la superficie de exutorios en el techo y la coordinación con puertas y cortinas de humo. Los resultados del estudio subrayan que la apertura de puertas para la entrada de aire a nivel bajo y el aumento de la superficie de exutorios mejoran significativamente la evacuación del humo, el control de la temperatura y la visibilidad en caso de incendio. Estos hallazgos destacan la efectividad de un diseño alternativo sin cortinas de humo y con mayor ventilación, comparado con las soluciones tradicionales que incluyen cortinas de humo. Sin embargo, se observan limitaciones en escenarios de crecimiento ultrarrápido del incendio, lo que sugiere la necesidad de sistemas más robustos y flexibles. El estudio también sugiere la importancia de una mayor investigación para mejorar estos sistemas de control en situaciones complejas, como incendios en múltiples ubicaciones dentro del almacén o cerca de puertas. Además, se destaca la relevancia de adherirse a normativas como el RSCIEI en España para garantizar la seguridad de los activos y el personal, y proteger la integridad de la cadena de suministro.es-ES
dc.description.abstractThis project evaluates the effectiveness of smoke control systems in logistics warehouses to mitigate fire risks. Current technologies and their integration with other protection measures are analyzed, emphasizing the importance of an appropriate design that includes optimizing the surface area of roof vents and coordinating with doors and smoke curtains. The study's results highlight that opening doors for low-level air intake and increasing the surface area of roof vents significantly improve smoke evacuation, temperature control, and visibility in the event of a fire. These findings underscore the effectiveness of an alternative design without smoke curtains and with enhanced ventilation compared to traditional solutions that include smoke curtains. However, limitations are observed in scenarios of ultra-rapid fire growth, suggesting the need for more robust and flexible systems. The study also suggests the importance of further research to improve these control systems in complex situations, such as fires in multiple locations within the warehouse or near doors. Additionally, it emphasizes the relevance of adhering to regulations like the RSCIEI in Spain to ensure the safety of assets and personnel and to protect the integrity of the supply chain.en-GB
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoes-ESes_ES
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 United Stateses_ES
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/us/es_ES
dc.subject.otherH62-mecanica (MII-M)es_ES
dc.titleEvaluación de sistemas de control de humo en almaceneses_ES
dc.typeinfo:eu-repo/semantics/masterThesises_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.keywordsControl de humo, Almacén logístico, Protección contra incendios, Exutorioes-ES
dc.keywordsSmoke control, Logistical warehouse, Fire protection, Smoke vent.en-GB
Aparece en las colecciones: H62-Trabajos Fin de Máster

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
TFM - Javier Revilla_signed.pdfTrabajo Fin de Máster10,44 MBAdobe PDFVista previa
Visualizar/Abrir
ANEXO B TFM J.REVILLA.pdfAutorización189,95 kBAdobe PDFVista previa
Visualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.