Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/11531/87319
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorRodríguez Pérez, Néstores-ES
dc.contributor.authorMatanza Domingo, Javieres-ES
dc.contributor.authorLópez López, Gregorioes-ES
dc.contributor.authorStojanovic, Vojislaves-ES
dc.date.accessioned2024-02-27T15:23:33Z-
dc.date.available2024-02-27T15:23:33Z-
dc.identifier.urihttp://hdl.handle.net/11531/87319-
dc.description.abstractes-ES
dc.description.abstractModbus TCP is a communication protocol widely used in industrial applications and to communicate with energy assets such as inverters or data loggers. The communications technologies involved in the management of distributed energy resources (DER) should prove their ability to include new units in the operation while fulfilling functional requirements.This paper studies the scalability performance of Modbus TCP protocol over Ethernet to monitor and control DER in a positive energy district (PED) environment. This use case is part of an Innovative Element (IE) being demonstrated in the city of Dijon within the RESPONSE project. The analysis was carried out considering different bit error ratios (BER) and number of servers. As performance indicator, the time spent by the client to poll all the servers (i.e., polling time) was measured, as it is the most restrictive functional requirement in the use case analysed, requiring it to be one minute.Results from simulations show how increasing BER and the number of devices in the network impact the total polling time. Despite the average polling time complied with the required one in most cases, its standard deviation significantly increased with BER. If the transmission medium presents a low BER, Modbus TCP has a great scalability potential to control and monitor devices that require data exchanges every minute. In addition, the maximum number of devices to keep a good performance is considered appropriate for its application in a PED environment. Future works may assess the impact of distance or topology on use case’s performance.en-GB
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoen-GBes_ES
dc.rightses_ES
dc.rights.uries_ES
dc.titleScalability evaluation of a Modbus TCP control and monitoring system for Distributed Energy Resourceses_ES
dc.typeinfo:eu-repo/semantics/workingPaperes_ES
dc.description.versioninfo:eu-repo/semantics/draftes_ES
dc.rights.accessRightsinfo:eu-repo/semantics/restrictedAccesses_ES
dc.keywordses-ES
dc.keywordsModbus TCP, Scalability, Distributed Energy Resources, Communication protocol, Ethernet, ICT, BER, Per-formance evaluationen-GB
Aparece en las colecciones: Documentos de Trabajo

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
IIT-22-135C.pdf1,09 MBAdobe PDFVisualizar/Abrir     Request a copy


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.