dc.description.abstractEl aumento significativo en el número de operaciones de los cambiadores de tomas en carga (OLTC) en transformadores de distribución HV/HV dentro de la red eléctrica española ha generado preocupaciones sobre el mantenimiento y la durabilidad del equipo. Este estudio tiene como objetivo analizar la correlación entre las operaciones de OLTC y las variaciones de voltaje, especialmente en el contexto del creciente uso de energías renovables. Al recopilar y analizar datos históricos de varias subestaciones, se identificaron patrones y tendencias que podrían explicar el aumento en los cambios de tomas. Los resultados sugieren que la inestabilidad del voltaje puede estar relacionada tanto con las acciones del operador de la red como con las operaciones de la empresa de distribución, lo que destaca la necesidad de estrategias de gestión avanzadas para mitigar los efectos negativos en la estabilidad y eficiencia de la red.es-ES
dc.description.abstractThe significant increase in the number of operations of On-Load Tap Changers (OLTC) in HV/HV distribution transformers within the Spanish electrical grid has raised concerns regarding the maintenance and durability of the equipment. This study aims to analyze the correlation between OLTC operations and voltage variations, particularly in the context of increasing renewable energy penetration. By collecting and analyzing historical data from various substations, patterns and trends that could explain the surge in tap changes were identified. The results suggest that voltage instability may be related to both the network operator's actions and the distribution company's operations, highlighting the need for advanced management strategies to mitigate negative effects on grid stability and efficiency.en-GB
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoen-GBes_ES
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 United Stateses_ES
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/us/es_ES
dc.subject.otherM8Ees_ES
dc.titleAssessment of increasing number of operations of On-Load Tap Changers (OLTC) in HV/HV distributions transformerses_ES
dc.typeinfo:eu-repo/semantics/masterThesises_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.keywordsCambiador de Tomas en Carga (OLTC) Transformadores de Distribución HV/HV Variaciones de Voltaje Penetración de Energías Renovables Estabilidad de la Red Análisis de Correlaciónes-ES
dc.keywordsOn-Load Tap Changer (OLTC) HV/HV Distribution Transformers Voltage Variations Renewable Energy Penetration Grid Stability Correlation Analysisen-GB
Aparece en las colecciones: M8E - Trabajos Fin de Máster

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
Irazabal Espinosa Julen S.pdfTrabajo Fin de Máster198,9 kBAdobe PDFVista previa
Visualizar/Abrir
Firma TFM (2).pdfAutorización40,86 kBAdobe PDFVista previa
Visualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.