Por favor, use este identificador para citar o enlazar este ítem:
http://hdl.handle.net/11531/92005
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.advisor | Egido Cortés, Ignacio | es-ES |
dc.contributor.advisor | Romero Gordón, José María | es-ES |
dc.contributor.author | Irazabal Espinosa, Julen | es-ES |
dc.contributor.other | Universidad Pontificia Comillas, Escuela Técnica Superior de Ingeniería (ICAI) | es_ES |
dc.date.accessioned | 2024-08-16T14:23:49Z | - |
dc.date.available | 2024-08-16T14:23:49Z | - |
dc.date.issued | 2024 | es_ES |
dc.identifier.uri | http://hdl.handle.net/11531/92005 | - |
dc.description | Master in Smart Grids | es_ES |
dc.description.abstract | El aumento significativo en el número de operaciones de los cambiadores de tomas en carga (OLTC) en transformadores de distribución HV/HV dentro de la red eléctrica española ha generado preocupaciones sobre el mantenimiento y la durabilidad del equipo. Este estudio tiene como objetivo analizar la correlación entre las operaciones de OLTC y las variaciones de voltaje, especialmente en el contexto del creciente uso de energías renovables. Al recopilar y analizar datos históricos de varias subestaciones, se identificaron patrones y tendencias que podrían explicar el aumento en los cambios de tomas. Los resultados sugieren que la inestabilidad del voltaje puede estar relacionada tanto con las acciones del operador de la red como con las operaciones de la empresa de distribución, lo que destaca la necesidad de estrategias de gestión avanzadas para mitigar los efectos negativos en la estabilidad y eficiencia de la red. | es-ES |
dc.description.abstract | The significant increase in the number of operations of On-Load Tap Changers (OLTC) in HV/HV distribution transformers within the Spanish electrical grid has raised concerns regarding the maintenance and durability of the equipment. This study aims to analyze the correlation between OLTC operations and voltage variations, particularly in the context of increasing renewable energy penetration. By collecting and analyzing historical data from various substations, patterns and trends that could explain the surge in tap changes were identified. The results suggest that voltage instability may be related to both the network operator's actions and the distribution company's operations, highlighting the need for advanced management strategies to mitigate negative effects on grid stability and efficiency. | en-GB |
dc.format.mimetype | application/pdf | es_ES |
dc.language.iso | en-GB | es_ES |
dc.rights | Attribution-NonCommercial-NoDerivs 3.0 United States | es_ES |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/us/ | es_ES |
dc.subject.other | M8E | es_ES |
dc.title | Assessment of increasing number of operations of On-Load Tap Changers (OLTC) in HV/HV distributions transformers | es_ES |
dc.type | info:eu-repo/semantics/masterThesis | es_ES |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | es_ES |
dc.keywords | Cambiador de Tomas en Carga (OLTC) Transformadores de Distribución HV/HV Variaciones de Voltaje Penetración de Energías Renovables Estabilidad de la Red Análisis de Correlación | es-ES |
dc.keywords | On-Load Tap Changer (OLTC) HV/HV Distribution Transformers Voltage Variations Renewable Energy Penetration Grid Stability Correlation Analysis | en-GB |
Aparece en las colecciones: | M8E - Trabajos Fin de Máster |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
Irazabal Espinosa Julen S.pdf | Trabajo Fin de Máster | 198,9 kB | Adobe PDF | Visualizar/Abrir |
Firma TFM (2).pdf | Autorización | 40,86 kB | Adobe PDF | Visualizar/Abrir |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.