Por favor, use este identificador para citar o enlazar este ítem:
http://hdl.handle.net/11531/94645
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.advisor | Cepeda Fernández, Fernando | es-ES |
dc.contributor.author | Asensio Blazquez, Javier | es-ES |
dc.contributor.other | Universidad Pontificia Comillas, Escuela Técnica Superior de Ingeniería (ICAI) | es_ES |
dc.date.accessioned | 2024-09-30T09:10:18Z | - |
dc.date.available | 2024-09-30T09:10:18Z | - |
dc.date.issued | 2025 | es_ES |
dc.identifier.uri | http://hdl.handle.net/11531/94645 | es_ES |
dc.description | Máster Universitario en Ingeniería Industrial + Máster en Industria Conectada / in Smart Industry | es_ES |
dc.description.abstract | El presente proyecto parte del cálculo detallado de las cargas térmicas en cada planta del edificio a estudiar, dichas cargas fueron calculadas tanto para invierno como para verano. Las cargas se obtuvieron considerando: - Condiciones exteriores e interiores de diseño: las condiciones exteriores fueron obtenidas a partir de la Guía Técnica – Condiciones climáticas de proyecto [3] además de contar con sus respectivas correcciones en función de la hora solar y orientación. Las condiciones interiores seleccionadas fueron las marcadas por el RITE; 25 ºC en verano, 21ºC en invierno . - Ocupación y uso de cada espacio/local. - Orientación y transmitancia térmica de los cerramientos, considerando tanto el vidrio como los muros y la cubierta. - Cargas internas como la iluminación y equipos. Con base en estas cargas se definen los equipos principales: - Enfriadoras por condensación de aire, responsables de cubrir las necesidades de refrigeración. - Calderas de gas, para la calefacción de invierno. - Unidades de Tratamiento de Aire (UTAs) para asegurar ventilación y calidad de aire interior. - Fan-coils distribuidos por cada planta y local, estos permiten dar cierta flexibilidad y confort individualizado. - Red de conductos, rejillas y difusores, todo ello garantiza una correcta distribución El modelo proyectado responde a una configuración de agua-aire, ampliamente utilizada en edificios industriales, como el actual siendo este un edificio de oficinas, ya que este sistema mantiene el equilibrio entre la eficiencia y la flexibilidad. | es-ES |
dc.description.abstract | This project is based on a detailed calculation of the thermal loads on each floor of the building under study. These loads were calculated for both winter and summer conditions. The loads were determined by considering: - Outdoor and indoor design conditions: outdoor conditions were obtained from the Technical Guide – Project Climate Conditions [3], including the corresponding corrections depending on solar time and orientation. Indoor conditions were set according to the RITE standard: 25 ºC in summer, 21 ºC in winter. - Occupancy and use of each space/room. - Orientation and thermal transmittance of the enclosures, considering both glazing and opaque walls/roof. - Internal loads such as lighting and equipment. Based on these loads, the main equipment was defined: - Air-cooled chillers, responsible for meeting cooling demand. - Gas boilers, for winter heating. - Air Handling Units (AHUs), to ensure ventilation and indoor air quality. - Fan-coils distributed across each floor and room, providing flexibility and individualized comfort. - Ductwork, grilles, and diffusers, guaranteeing proper air distribution. The proposed model is based on a water-air configuration, widely used in industrial buildings—here applied to an office building—as it balances both efficiency and flexibility. | en-GB |
dc.format.mimetype | application/pdf | es_ES |
dc.language.iso | es-ES | es_ES |
dc.rights | Attribution-NonCommercial-NoDerivs 3.0 United States | es_ES |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/us/ | es_ES |
dc.subject.other | H62-mecanica (MII-M) | es_ES |
dc.title | CLIMATIZACIÓN DE UN EDIFICIO INDUSTRIAL EN MADRID | es_ES |
dc.type | info:eu-repo/semantics/masterThesis | es_ES |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | es_ES |
dc.keywords | Palabras clave: Climatización, cargas térmicas, Enfriadora, Caldera | es-ES |
dc.keywords | Keywords: HVAC, Thermal loads, Chiller, Boiler | en-GB |
Aparece en las colecciones: | TFG, TFM (temporales) |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
TFM MII - Asensio Blazquez, Javier.pdf | Trabajo Fin de Máster | 12,27 MB | Adobe PDF | Visualizar/Abrir |
Anexo I.pdf | Autorización | 1,24 MB | Adobe PDF | Visualizar/Abrir |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.