• A Quasi-Wireless Intraoperatory Neurophysiological Monitoring System 

      Alonso Rivas, Eduardo; Giannetti, Romano; Rodríguez-Morcillo García, Carlos; Matanza Domingo, Javier; Muñoz Frías, José Daniel; Scandurra, Graziella; Ciofi, Carmine; Vega-Zelaya, Lorena; Pastor, Jesús (2022-11-27)
      Intraoperative Neurophysiological Monitoring is a set of monitoring techniques that reads electrical activity generated by the nervous system structures during surgeries. In non-trivial surgeries, neurophysiologists require ...
    • Temperature controlled multi-oven for MTF tests 

      Ciofi, Carmine; Giannetti, Romano; Neri, Bruno (Sin editorial (Saint Paul, Estados Unidos de América), 01/06/1998)
      The design and principle of operation of a measurement system primarily intended for performing MTF (median time to failure) tests on metallic interconnections of integrated circuit is presented. The instrument is different ...
    • True constant temperature measurement system for lifetime tests of metallic interconnections of IC's 

      Ciofi, Carmine; Giannetti, Romano; Neri, Bruno (01/10/1998)
      The design and principle of operation of a measurement system for performing reliability tests on integrated circuit metallic interconnections is presented. The instrument is controlled by a personal computer which sets ...
    • Ultra low noise current sources 

      Ciofi, Carmine; Giannetti, Romano; Dattilo, Vincenzino; Neri, Bruno (Sin editorial (Ottawa, Canadá), 19/05/1997)
      The current sources which are normally used in research laboratories are not suitable for low noise measurement systems because of the unacceptable level of low frequency noise which they introduce in the measurement chain. ...
    • Ultra low noise, current to voltage converter with offset compensation independent of the source impedance 

      Ciofi, Carmine; Festa, G.; Giannetti, Romano; Neri, Bruno (Sin editorial (Saint Paul, Estados Unidos de América), 01/06/1998)
      A new version of a low-noise, high gain transimpedance amplifier, operating in the frequency range from DC to KHz, is described. The new version of the instrument, thanks to a completely differential architecture, is capable ...
    • Ultra low-noise current sources 

      Ciofi, Carmine; Giannetti, Romano; Dattilo, Vincenzino; Neri, Bruno (01/02/1998)
      The solid state DC current sources available on the market are not suitable for applications in low noise measurement systems because of the high level of low-frequency noise introduced in the measurement chain. The most ...