• English
    • español
  • español 
    • English
    • español
  • Login
Ver ítem 
  •   DSpace Principal
  • 2.- Investigación
  • Artículos
  • Ver ítem
  •   DSpace Principal
  • 2.- Investigación
  • Artículos
  • Ver ítem
JavaScript is disabled for your browser. Some features of this site may not work without it.

Comparative analysis of surface roughness and plastic deformation of reciprocating instruments after clinical use

Thumbnail
Ver/
IIT-24-241R (2.416Mb)
IIT-24-241R_preview (3.712Kb)
Fecha
2024-08-02
Autor
Herrera Martín, Ángel
Azabal, Magdalena
Jiménez Octavio, Jesús Ramón
del Real Romero, Juan Carlos
López de Armentia Hernández, Sara
Asensio Gil, Juan Manuel
Arias Paniagua, Ana María
Estado
info:eu-repo/semantics/publishedVersion
Metadatos
Mostrar el registro completo del ítem
Mostrar METS del ítem
Ver registro en CKH

Refworks Export

Resumen
 
 
This study assessed the surface topography and plastic deformation (PD) of new and used contemporary reciprocating instruments. Twenty-six WaveOne Gold (WOG) and EdgeOne Fire (EO) instruments were photographed under magnification. The instruments were randomly assigned to a control group of new instruments preserved for surface roughness analysis (n = 6 each), or to an experimental group to shape the root canal system of a single molar (n = 20 each), making a total of four groups (WOGnew, EOnew, WOGused, EOused). Used instruments were also photographed after instrumentation. The presence of fractures was registered. Preoperative and postoperative images were randomly ordered for evaluation. Two blinded calibrated examiners evaluated the presence of PD. Inter-observer agreement was calculated with the Kappa coefficient (K = 0.89). 3D profilometry was also used for the surface roughness analysis of six randomly selected instruments from the WOGused and EOused groups. Chi-square and two-way ANOVA tests were used to, respectively, compare PD and changes in surface roughness among the groups. No instruments fractured; however, a significantly greater percentage of EO instruments suffered plastic deformation than WOG instruments (p < 0.001), (OR = 11.09 (CI 95 2.6–56.3)). The overall surface roughness was higher for most parameters in the EO instruments (p < 0.05). Single uses of EO instruments produced significantly higher chances of PD and increased surface roughness values compared to WOG.
 
URI
https:doi.org10.3390ma17163978
http://hdl.handle.net/11531/100666
Comparative analysis of surface roughness and plastic deformation of reciprocating instruments after clinical use
Tipo de Actividad
Artículos en revistas
ISSN
1996-1944
Materias/ categorías / ODS
Instituto de Investigación Tecnológica (IIT)
Palabras Clave

surface roughness; WaveOne gold; EdgeOne fire; profilometry; plastic deformation; nickel–titanium; root canal preparation; Ni-Ti file
Colecciones
  • Artículos

Repositorio de la Universidad Pontificia Comillas copyright © 2015  Desarrollado con DSpace Software
Contacto | Sugerencias
 

 

Búsqueda semántica (CKH Explorer)


Listar

Todo DSpaceComunidades & ColeccionesPor fecha de publicaciónAutoresTítulosMateriasPor DirectorPor tipoEsta colecciónPor fecha de publicaciónAutoresTítulosMateriasPor DirectorPor tipo

Mi cuenta

AccederRegistro

Repositorio de la Universidad Pontificia Comillas copyright © 2015  Desarrollado con DSpace Software
Contacto | Sugerencias