Impact assessment of FCUC on optimal design of UFLS settings in Island Power Systems

Thumbnail
View/Open
IIT-23-342C.pdf (573.6Kb)
Date
2023-12-22
Author
Lobato Miguélez, Enrique
Sigrist, Lukas
Rajabdorri, Mohammad
Egido Cortés, Ignacio
Estado
info:eu-repo/semantics/publishedVersion
Metadata
Show full item record
Mostrar METS del ítem
Ver registro en CKH

Refworks Export

Abstract
A frequency constrained unit commitment (FCUC) formulates the non-linear, non-convex frequency dynamics to obtain the generation dispatch of island power systems (IPSs). Even with FCUC, under frequency load shedding (UFLS) is inevitable for sufficiently large contingencies. The objective of this paper is to assess how generation dispatches obtained by FCUC affect and change optimal settings of UFLS schemes and the associated dynamic performance. By using a real-world Spanish island, the UFLS scheme is optimally tuned for both the standard unit commitment (STUC) and the FCUC. The dynamic performance of both UFLS schemes are compared in terms of average shed load and frequency nadir values after each generator outage. Results show that FCUC increases the IPS cost by 10.8, but the improvement in the dynamic frequency response is not fully exploited unless the UFLS scheme settings are re-tuned for the new optimal dispatch.
 
A frequency constrained unit commitment (FCUC) formulates the non-linear, non-convex frequency dynamics to obtain the generation dispatch of island power systems (IPSs). Even with FCUC, under frequency load shedding (UFLS) is inevitable for sufficiently large contingencies. The objective of this paper is to assess how generation dispatches obtained by FCUC affect and change optimal settings of UFLS schemes and the associated dynamic performance. By using a real-world Spanish island, the UFLS scheme is optimally tuned for both the standard unit commitment (STUC) and the FCUC. The dynamic performance of both UFLS schemes are compared in terms of average shed load and frequency nadir values after each generator outage. Results show that FCUC increases the IPS cost by 10.8, but the improvement in the dynamic frequency response is not fully exploited unless the UFLS scheme settings are re-tuned for the new optimal dispatch.
 
URI
http://hdl.handle.net/11531/105332
Impact assessment of FCUC on optimal design of UFLS settings in Island Power Systems
Tipo de Actividad
Capítulos en libros
Materias/ categorías / ODS
Instituto de Investigación Tecnológica (IIT)
Palabras Clave
island power systems, load shedding, unit commitment, frequency stability
island power systems, load shedding, unit commitment, frequency stability
Collections
  • Artículos

Repositorio de la Universidad Pontificia Comillas copyright © 2015  Desarrollado con DSpace Software
Contact Us | Send Feedback
 

 

Búsqueda semántica (CKH Explorer)


Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsxmlui.ArtifactBrowser.Navigation.browse_advisorxmlui.ArtifactBrowser.Navigation.browse_typeThis CollectionBy Issue DateAuthorsTitlesSubjectsxmlui.ArtifactBrowser.Navigation.browse_advisorxmlui.ArtifactBrowser.Navigation.browse_type

My Account

LoginRegister

Repositorio de la Universidad Pontificia Comillas copyright © 2015  Desarrollado con DSpace Software
Contact Us | Send Feedback