• English
    • español
  • English 
    • English
    • español
  • Login
View Item 
  •   Home
  • 2.- Investigación
  • Artículos
  • View Item
  •   Home
  • 2.- Investigación
  • Artículos
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

The Effect of Dynamic Injurious Axial Impact on Human Cervical Intervertebral Disc Pressure Response: Methodology & Initial Results

Thumbnail
View/Open
IIT-26-018R (6.596Mb)
IIT-26-018R_preview (3.875Kb)
Date
2026-01-02
Author
Sochor, Sara
Sochor, Mark
Asensio Gil, Juan Manuel
Rodríguez-Morcillo García, Carlos
López Valdés, Francisco José
Estado
info:eu-repo/semantics/publishedVersion
Metadata
Show full item record
Mostrar METS del ítem
Ver registro en CKH

Refworks Export

Abstract
Cervical spine (c-spine) injuries are a prominent concern in sporting activities, and dynamic axial (i.e., head-first) impacts are associated with a high risk of c-spine trauma. This methodology study implanted pressure sensors in post-mortem human subject (PMHS) cervical intervertebral discs (CIVDs) to assess biomechanical response and disc pressure changes during dynamic injurious axial impacts. Two fresh frozen male head–neck PMHS (cephalus with complete c-spine) were instrumented with miniature pressure sensors (Model 060S, Precision Measurement Company, Ann Arbor, MI, USA) at three CIVD levels (upper, middle, and lower c-spine). Experiments replicated the Nightingale et al. studies, simulating a rigid unconstrained head vertex (0°) axial impact. PMHS were raised to a drop height of 0.53 m to reach the desired impact velocity of ~3.2 m/s and were allowed to drop vertically. Results showed characteristic c-spine deformations/buckling motion patterns and marked CIVD pressure differences between CIVD levels. The more cranial (C2–C4) and caudal (C6–T1) CIVD exhibited greater and more comparable pressure values than those of the mid-spine (C4–C6), and the pressure in upper/lower levels was at least ~four to six times higher than that of the middle. This study establishes the feasibility and assesses the potential of CIVD pressure as a biomechanical metric for assessing injurious axial loading and contributes a novel experimental framework for future injury tolerance research and model validation.
 
Cervical spine (c-spine) injuries are a prominent concern in sporting activities, and dynamic axial (i.e., head-first) impacts are associated with a high risk of c-spine trauma. This methodology study implanted pressure sensors in post-mortem human subject (PMHS) cervical intervertebral discs (CIVDs) to assess biomechanical response and disc pressure changes during dynamic injurious axial impacts. Two fresh frozen male head–neck PMHS (cephalus with complete c-spine) were instrumented with miniature pressure sensors (Model 060S, Precision Measurement Company, Ann Arbor, MI, USA) at three CIVD levels (upper, middle, and lower c-spine). Experiments replicated the Nightingale et al. studies, simulating a rigid unconstrained head vertex (0°) axial impact. PMHS were raised to a drop height of 0.53 m to reach the desired impact velocity of ~3.2 m/s and were allowed to drop vertically. Results showed characteristic c-spine deformations/buckling motion patterns and marked CIVD pressure differences between CIVD levels. The more cranial (C2–C4) and caudal (C6–T1) CIVD exhibited greater and more comparable pressure values than those of the mid-spine (C4–C6), and the pressure in upper/lower levels was at least ~four to six times higher than that of the middle. This study establishes the feasibility and assesses the potential of CIVD pressure as a biomechanical metric for assessing injurious axial loading and contributes a novel experimental framework for future injury tolerance research and model validation.
 
URI
https://doi.org/10.3390/app16020872
http://hdl.handle.net/11531/108196
The Effect of Dynamic Injurious Axial Impact on Human Cervical Intervertebral Disc Pressure Response: Methodology & Initial Results
Tipo de Actividad
Artículos en revistas
ISSN
2076-3417
Materias/ categorías / ODS
Instituto de Investigación Tecnológica (IIT)
Palabras Clave
biomechanics; cervical spine; neck; intervertebral disc; axial impact; cadaver; PMHS; pressure; dynamic; injury prevention
biomechanics; cervical spine; neck; intervertebral disc; axial impact; cadaver; PMHS; pressure; dynamic; injury prevention
Collections
  • Artículos

Repositorio de la Universidad Pontificia Comillas copyright © 2015  Desarrollado con DSpace Software
Contact Us | Send Feedback
 

 

Búsqueda semántica (CKH Explorer)


Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsxmlui.ArtifactBrowser.Navigation.browse_advisorxmlui.ArtifactBrowser.Navigation.browse_typeThis CollectionBy Issue DateAuthorsTitlesSubjectsxmlui.ArtifactBrowser.Navigation.browse_advisorxmlui.ArtifactBrowser.Navigation.browse_type

My Account

LoginRegister

Repositorio de la Universidad Pontificia Comillas copyright © 2015  Desarrollado con DSpace Software
Contact Us | Send Feedback