Mostrar el registro sencillo del ítem

dc.contributor.authorPérez Caldentey, Alejandroes-ES
dc.contributor.authorGutiérrez Diego, Yolandaes-ES
dc.contributor.authorArinez Fernandez, Freddyes-ES
dc.contributor.authorSantos, Anastasio Pes-ES
dc.date.accessioned2026-02-02T06:59:03Z
dc.date.available2026-02-02T06:59:03Z
dc.date.issued2021-05-04es_ES
dc.identifier.issn0141-0296es_ES
dc.identifier.urihttps://doi.org/10.1016/j.engstruct.2021.112411es_ES
dc.identifier.urihttp://hdl.handle.net/11531/108468
dc.descriptionArtículos en revistases_ES
dc.description.abstractEste artículo presenta los resultados de un ensayo experimental a escala real sobre la robustez de un edificio de dos plantas de hormigón armado con losas macizas, sometido a la eliminación súbita de un pilar de esquina. La estructura, no diseñada específicamente para este tipo de acción accidental, mostró un comportamiento robusto, con daños relativamente limitados. La flecha máxima registrada fue de aproximadamente 22 cm y los patrones de fisuración observados fueron moderados y controlados. Tras la retirada del pilar, la losa comenzó a trabajar de forma similar a un elemento simplemente apoyado a lo largo del eje de simetría, sustentado únicamente por tres pilares. El ensayo fue reproducido mediante modelos de elementos finitos con LS-DYNA, obteniéndose una muy buena correlación entre los resultados numéricos y experimentales, tanto en deformaciones como en patrones de fisuración. No obstante, se detectaron fisuras torsionales en la conexión pilar–losa, lo que sugiere que este detalle constructivo puede ser crítico y potencialmente determinante para la estabilidad a medio plazo de la estructura.es-ES
dc.description.abstractThis paper presents the results of a full-scale robustness test carried out on a two-storey reinforced concrete building with solid slabs, in which a corner column was suddenly removed. Despite the extreme nature of the action and the fact that the structure was not designed to resist column loss, the observed damage was relatively minor, with a maximum deflection of about 22 cm and controlled cracking patterns. After column removal, the slab behaved mainly as a simply supported system along the symmetry axis, supported by only three columns. The experiment was simulated using finite element analysis with LS-DYNA, achieving very good agreement with the experimental results in terms of deflections and crack patterns. Although the immediate response indicated adequate robustness, the appearance of torsional cracking at the slab–column connection suggested possible progressive deterioration of this joint. This highlights the importance of connection behaviour in robustness assessments and the need to complement global analyses with a detailed evaluation of slab–column connections.en-GB
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoen-GBes_ES
dc.rightsCreative Commons Reconocimiento-NoComercial-SinObraDerivada Españaes_ES
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/es_ES
dc.sourceRevista: Engineering Structures, Periodo: 1, Volumen: , Número: 240, Página inicial: ., Página final: .es_ES
dc.titleTesting robustness: A full-scale experimental test on a two-storey reinforced concrete frame with solid slabses_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.description.versioninfo:eu-repo/semantics/publishedVersiones_ES
dc.rights.holderes_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.keywordsRobustez, Eliminación De Columnas, Hormigón Armado, Análisis Por Elementos Finitos, Ensayo A Escala Reales-ES
dc.keywordsRobustness, Column Removal, Reinforced Concrete, Finite Element Modelling, Full Scale Testingen-GB


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

  • Artículos
    Artículos de revista, capítulos de libro y contribuciones en congresos publicadas.

Mostrar el registro sencillo del ítem

Creative Commons Reconocimiento-NoComercial-SinObraDerivada España
Excepto si se señala otra cosa, la licencia del ítem se describe como Creative Commons Reconocimiento-NoComercial-SinObraDerivada España