Show simple item record

dc.contributor.authorTomás Martín, Andréses-ES
dc.contributor.authorRoldan Perez, Javieres-ES
dc.contributor.authorJankovic, Njegoses-ES
dc.contributor.authorYague Yague, Sauro Josées-ES
dc.contributor.authorSigrist, Lukases-ES
dc.contributor.authorGarcía Cerrada, Aurelioes-ES
dc.date.accessioned2026-03-27T05:20:12Z
dc.date.available2026-03-27T05:20:12Z
dc.date.issued2026-04-01es_ES
dc.identifier.issn0142-0615es_ES
dc.identifier.urihttps://doi.org/10.1016/j.ijepes.2026.111797es_ES
dc.identifier.urihttp://hdl.handle.net/11531/109386
dc.descriptionArtículos en revistases_ES
dc.description.abstractMicrogrids (MGs) can work either connected to or disconnected from the main grid, and seamless transition between modes is essential for reliable operation. Even though centralised secondary controllers are the obvious choice to resynchronise MGs with the main grid, and to control their power exchange, decentralised multi-agent secondary controllers have been proposed recently because they simplify the communication system required. However, aspects such as communication delays and implementation details have not received enough attention. This paper describes an improved decentralised multi-agent secondary controller based on consensus to resynchronise a MG with the main grid and control the power exchange afterwards. The effects of communication delays between agents and the potentially dangerous active power transients required to synchronise the MG were studied by small signal stability analysis and numerical simulations. The paper shows that both problems can be addressed with a systematic design of the decentralised secondary controller combined with derivative droop primary controllers. Results were validated in a real MG consisting of four 15 kVA power converters, electrical lines and loads, a 75 kVA grid emulator, and an industrial communication infrastructure. The proposed algorithm has been validated in a large system consisting of 69 buses, which includes seven grid-forming converters and primarily resistive lines. Additionally, the algorithm has been tested in scenarios with limited available energy from the converters and taking into account the control of the voltage amplitude difference between the microgrid and the main grid.es-ES
dc.description.abstractMicrogrids (MGs) can work either connected to or disconnected from the main grid, and seamless transition between modes is essential for reliable operation. Even though centralised secondary controllers are the obvious choice to resynchronise MGs with the main grid, and to control their power exchange, decentralised multi-agent secondary controllers have been proposed recently because they simplify the communication system required. However, aspects such as communication delays and implementation details have not received enough attention. This paper describes an improved decentralised multi-agent secondary controller based on consensus to resynchronise a MG with the main grid and control the power exchange afterwards. The effects of communication delays between agents and the potentially dangerous active power transients required to synchronise the MG were studied by small signal stability analysis and numerical simulations. The paper shows that both problems can be addressed with a systematic design of the decentralised secondary controller combined with derivative droop primary controllers. Results were validated in a real MG consisting of four 15 kVA power converters, electrical lines and loads, a 75 kVA grid emulator, and an industrial communication infrastructure. The proposed algorithm has been validated in a large system consisting of 69 buses, which includes seven grid-forming converters and primarily resistive lines. Additionally, the algorithm has been tested in scenarios with limited available energy from the converters and taking into account the control of the voltage amplitude difference between the microgrid and the main grid.en-GB
dc.language.isoen-GBes_ES
dc.sourceRevista: International Journal of Electrical Power & Energy Systems, Periodo: 1, Volumen: online, Número: , Página inicial: 111797-1, Página final: 111797-12es_ES
dc.subject.otherInstituto de Investigación Tecnológica (IIT)es_ES
dc.titleImprovements of a multi-agent secondary controller for reconnecting a microgrid to the main grides_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.description.versioninfo:eu-repo/semantics/publishedVersiones_ES
dc.rights.holderes_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.keywordsMicrogrid; Synchronisation; Decentralised control; Multi-agent systems; Small-signal stabilityes-ES
dc.keywordsMicrogrid; Synchronisation; Decentralised control; Multi-agent systems; Small-signal stabilityen-GB


Files in this item

Thumbnail
Thumbnail

This item appears in the following Collection(s)

  • Artículos
    Artículos de revista, capítulos de libro y contribuciones en congresos publicadas.

Show simple item record