Estudio del impacto de la pérdida de una fase en los sistemas de alimentación exterior de una central nuclear

Thumbnail
Ver/
Trabajo fin de grado (1.649Mb)
Autorización (306.4Kb)
Fecha
2014
Autor
Pontes Jiménez, Alfonso
Director/Coordinador
Rouco Rodríguez, Luis
Metadatos
Mostrar el registro completo del ítem
Mostrar METS del ítem
Ver registro en CKH

Refworks Export

Resumen
Este proyecto ha abordado el estudio del impacto de la pérdida de una fase en los sistemas de alimentación exterior de una central nuclear con una configuración muy común. En la configuración estudiada, el generador está conectado a la red a 400 kV a través del transformador principal. La red a 400 kV es la red de transporte a la cual la central vierte su producción. Se considera que existe interruptor de generación, que permite aislar el generador del resto del sistema eléctrico de la central, permitiendo que, en caso de parada del grupo, el sistema eléctrico de la central quede alimentado desde la red a 400 kV a través del transformador principal y del transformador auxiliar. El sistema eléctrico de la central también puede estar alimentado de una red a 138 kV a través del transformador de arranque. Este proyecto parte de un evento ocurrido en la central nuclear Byron (IL, USA). El proyecto ha considerado el análisis que hizo del evento de la central nuclear Byron la Comisión Regulatoria Nuclear (NRC) del gobierno de los Estados Unidos y el planteamiento metodológico propuesto por el Electric Power Research Institute (EPRI) también de los Estados Unidos.
 
This final degree project has studied the impact of an open-phase fault in the external power system of a nuclear power plant which power system exhibits a common configuration. In case of such configuration, the generator is connected through the main transformer to 400 kV network, which is the transmission network that receives the power plant production. The plant has a generator circuit breaker which isolates the generator from the plant electric power system. In case that the generator is disconnected from the network, the plant electric power system remains fed by the 400 kV network through the main transformer and the station auxiliary transformer. The plant electric power systems may also be fed by a 138 kV network through the start-up transformer. This project has been motivated by an event occurred at Byron’s nuclear plant (IL, USA). The project has considered the analysis of this event made the US Nuclear Regulatory Commission (NRC) and also the work made by the Electric Power Research Institute (EPRI), also from the United States.
 
URI
http://hdl.handle.net/11531/1360
Trabajo Fin de Grado
Estudio del impacto de la pérdida de una fase en los sistemas de alimentación exterior de una central nuclear
Titulación / Programa
Grado en Ingeniería Electromecánica
Colecciones
  • KL0-Trabajos Fin de Grado

Repositorio de la Universidad Pontificia Comillas copyright © 2015  Desarrollado con DSpace Software
Contacto | Sugerencias
 

 

Búsqueda semántica (CKH Explorer)


Listar

Todo DSpaceComunidades & ColeccionesPor fecha de publicaciónAutoresTítulosMateriasPor DirectorPor tipoEsta colecciónPor fecha de publicaciónAutoresTítulosMateriasPor DirectorPor tipo

Mi cuenta

AccederRegistro

Repositorio de la Universidad Pontificia Comillas copyright © 2015  Desarrollado con DSpace Software
Contacto | Sugerencias