dc.description.abstractSecurity-constrained unit commitment (SCUC) problem is one of the necessary tools for system operators to make operational planning and real-time operation. The internalization of transmission-network and security constraints (e.g. N-1 criterion) could lead to different decisions in the generation dispatch. However, the computational burden of this problem is challenging mainly due to its inherent large problem size. Therefore, this paper proposes an N-1 security constrained formulation based on the Line Outage Distribution Factors (LODF) instead of the one based on Injection Sensitivity Factors (ISF). This formulation is at the same time more compact than analogous formulations for contingency constraints; hence, it presents a lower computational burden. The computational efficiency of the proposed formulation is shown by solving the SCUC of the IEEE 118 bus system with LODF and ISF. Additionally, an iterative methodology for filtering the active N-1 congestion constraints is detailed, and its implementation for large-scale systems is described. The results show that the proposed filter reduces the computational time by approximately 70 in comparison to the complete formulation of N-1 constraints in SCUC.en-GB
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoen-GBes_ES
dc.rightses_ES
dc.rights.uries_ES
dc.sourceRevista: IEEE Transactions on Power Systems, Periodo: 1, Volumen: online, Número: 1, Página inicial: 329, Página final: 337es_ES
dc.subject.otherInstituto de Investigación Tecnológica (IIT)es_ES
dc.titleSecurity constrained unit commitment using line outage distribution factorses_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.description.versioninfo:eu-repo/semantics/publishedVersiones_ES
dc.rights.accessRightsinfo:eu-repo/semantics/restrictedAccesses_ES
dc.keywordses-ES
dc.keywordsmixed-integer linear programming (MIP), security constrained unit commitment (SCUC), line outage distribution factors (LODF), N-1 criterion.en-GB


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

  • Artículos
    Artículos de revista, capítulos de libro y contribuciones en congresos publicadas.

Mostrar el registro sencillo del ítem