Sistema de medida de tensión arterial en dedos con fotopletismografía: sistema de oclusión.

Thumbnail
View/Open
TFGM (5.423Mb)
ANXI (381.5Kb)
Date
2018
Author
Martín Parages, Carlos
Metadata
Show full item record
Mostrar METS del ítem
Ver registro en CKH

Refworks Export

Abstract
En este proyecto se explica el proceso utilizado para el diseño de un sistema de oclusión para dedo. El objetivo final de este desarrollo es la obtención de un sistema de medida de la tensión arterial en un lugar menos invasivo que el utilizado actualmente. Para realizar la medida de tensión arterial, se pretende utilizar junto al sistema de oclusión desarrollado, un sistema de medida de pletismografía (PPG) de manera a analizar las variaciones en la curva pletismográfica con respecto a la presión ejercida sobre el dedo y así obtener las presiones sistólica y diastólica. Para la obtención de un sistema que responda a las necesidades establecidas, se han estudiado diversos posibles métodos para la oclusión. Para diseñar un sistema que realizase la oclusión del dedo, así como incorporase los componentes necesarios para la medida de la fuerza, se diseñaron un conjunto de piezas mediante SolidEdge. Una vez montado el sistema completo se realizaron ensayos de calibración del sistema, obteniendo valores de la fuerza ejercida en función de la alimentación del actuador y de la posición del vástago. Como calibrado de la presión se ha utilizado la fórmula teórica que relaciona la fuerza y la presión. Los resultados obtenidos para el prototipo son prometedores dado que se ha conseguido obtener un sistema que permite ocluir de manera controlada la presión ejercida y tomar medidas de esta.
 
This project explains the process used to design a finger occlusion system. The goal of this project is to obtain a blood pressure measurement in a less invasive way than the currently used. To perform the blood pressure measurement, it is intended to use, together with the developed occlusion system, a plethysmography measurement system (PPG) in order to analyse the variations in the plethysmographic curve with respect to the pressure exerted on the finger and thus obtain the systolic and diastolic pressures. To obtain a system that meets the established needs, several possible methods for occlusion have been studied. To design a system able to perform the occlusion of the finger, as well as incorporate the necessary components for the measurement of the force, a set of pieces was design in SolidEdge. Once the complete system was installed, system calibration tests were carried out, obtaining values of the force exerted as a function of the actuator power supply and the position of the plunger. As a calibration of the pressure, the theoretical formula that relates force and pressure has been used. The results obtained for the prototype are promising given that it has been possible to obtain a system that allows controlled pressure to be occluded and measures taken.
 
URI
http://hdl.handle.net/11531/22580
Trabajo Fin de Máster
Sistema de medida de tensión arterial en dedos con fotopletismografía: sistema de oclusión.
Titulación / Programa
Se trata de estudiar la viabilidad y en su caso diseñar un sistema que permita medir la tensión arterial mediante un sistema de oclusión de las arterias de los dedos, midiendo la misma con métodos fotopletismográficos. Esta parte se refiere al sistema de oclusión controlada de las arterias del dedo.
Materias/ categorías / ODS
MII-N (H62-electronica)
Palabras Clave
PPG oclusión tensión presión diástole sístole
PPG occlusion pressure diastole systole
Collections
  • H62-Trabajos Fin de Máster

Repositorio de la Universidad Pontificia Comillas copyright © 2015  Desarrollado con DSpace Software
Contact Us | Send Feedback
 

 

Búsqueda semántica (CKH Explorer)


Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsxmlui.ArtifactBrowser.Navigation.browse_advisorxmlui.ArtifactBrowser.Navigation.browse_typeThis CollectionBy Issue DateAuthorsTitlesSubjectsxmlui.ArtifactBrowser.Navigation.browse_advisorxmlui.ArtifactBrowser.Navigation.browse_type

My Account

LoginRegister

Repositorio de la Universidad Pontificia Comillas copyright © 2015  Desarrollado con DSpace Software
Contact Us | Send Feedback