dc.contributor.advisor | García González, Adela | |
dc.contributor.author | Tapia Castejón, Juan Carlos | |
dc.contributor.other | Universidad Pontificia Comillas, Escuela Universiaria de Enfermería Y Fisioterapia | es_ES |
dc.date.accessioned | 2017-11-27T10:31:13Z | |
dc.date.available | 2017-11-27T10:31:13Z | |
dc.date.issued | 2017 | |
dc.identifier.uri | http://hdl.handle.net/11531/24189 | |
dc.description | Titulación::Postgrado::Máster Universitario en Biomecánica y Fisioterapia Deportiva | es_ES |
dc.description.abstract | La medición del rango articular (ROM) es importante para cuantificar la pérdida de normalidad del movimiento en cualquier estructura corporal, así como la ganancia de la misma tras la realización de un tratamiento o durante un período de recuperación tras haber sufrido una lesión. Además, llevar a cabo mediciones periódicas del ROM en deportistas parece necesario para la prevención de lesiones. Una manera de objetivar el mantenimiento o el cambio en el ROM es la utilización de goniómetros más modernos que el goniómetro manual para reducir al máximo el posible error que pudiera darse en la medida.
Objetivo: Validar el goniómetro digital (GD) Hawk HCT como instrumento de medida para la flexo-extensión de rodilla, conocer el error del aparato de medida y comprobar que la medición realizada es precisa, siendo ésta comparada con el sistema de análisis de movimiento (SAM).
Hipótesis: La utilización del GD Hawk HCT para medir los grados de movimiento de la articulación de la rodilla o ROM, velocidad (V) y aceleración (A) es igual de fiable que si se utilizan sistemas más complejos y/o ya validados para el mismo fin, como el SAM BTS SMART-DX.
Metodología: Consiste en un estudio analítico, observacional, transversal y unicéntrico que se llevará a cabo con un único sujeto, el cual realizará movimientos de flexo-extensión de rodilla de forma libre. Se recogerán los datos de ROM, V y A de forma simultánea utilizando dos herramientas de medición, que serán comparadas posteriormente. Las herramientas de medición son: el GD Hawk HCT y el SAM BTS SMART-DX. El programa utilizado para el análisis de los resultados obtenidos es el IBM SPSS Statistics 22.0.0.0. | es_ES |
dc.description.abstract | The measurement of the joint range of motion (ROM) is critical to quantify the loss of motion normality in any body structure. This measurement will also allow to estimate how the loss of motion normality is affected after a specific treatment or during the recovery period of an injury. Furthermore, the periodic measurement of the ROM in professional athletes seems to be essential to prevent injuries. The usage of modern goniometers rather than old fashion ones, will minimize the measurement error enabling a better identification of the variation in the ROM.
Objective: Validate a digital goniometer (GD) Hawk HTC used to measure the knee flexion and extension, find the device measurement error and verify the measurement accurateness against the motion analysis system (SAM).
Hypothesis: The reliability level of a GD to quantify the knee degree of motion, the velocity (V) and the acceleration (A) is comparable to other complex and previously validated systems, as in the case of SAM.
Methodology: Observational, transversal and analytical study performed to a single subject conducting free flexion-extension movements. Measurement data of ROM, V and A will be taken simultaneously using two different devices, that are going to be compared to each other. A GD Hawk HTC and the SAM BTS SMART-DX will be used for this purpose. The statistical analysis is going to be performed using IBM SPSS Statistics 22.0.0.0. | es_ES |
dc.format.mimetype | application/pdf | es_ES |
dc.language.iso | es | es_ES |
dc.subject | UNESCO::32 Medicina::3213 Cirugía::321311 Fisioterapia | es_ES |
dc.subject | UNESCO::24 Ciencias de la vida::2411 Fisiología humana::241118 Fisiología del movimiento | es_ES |
dc.subject | UNESCO::24 Ciencias de la vida::2402 Antropología física::240203 Antropometría y antropología forense | es_ES |
dc.title | Validación del goniómetro digital Hawk HCT como herramienta de medida para la flexo-extensión de rodilla | es_ES |
dc.type | info:eu-repo/semantics/masterThesis | es_ES |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | es_ES |
dc.keywords | Goniómetro digital, Sistema de Análisis de Movimiento, ROM, Velocidad, Aceleración | es_ES |
dc.keywords | Digital goniometer, Motion Analysis System, ROM, Velocity, Acceleration | es_ES |