• English
    • español
  • español 
    • English
    • español
  • Login
Ver ítem 
  •   DSpace Principal
  • 2.- Investigación
  • Artículos
  • Ver ítem
  •   DSpace Principal
  • 2.- Investigación
  • Artículos
  • Ver ítem
JavaScript is disabled for your browser. Some features of this site may not work without it.

A parametric study of hard tissue injury prediction using finite elements: consideration of geometric complexity, subfailure material properties, CT-thresholding and element characteristics

Thumbnail
Ver/
IIT-10-079A.pdf (342.5Kb)
Fecha
09/06/2010
Autor
Arregui-Dalmases, Carlos
Pozo de Dios, Eduardo del
Duprey, Sonia
López Valdés, Francisco José
Lau, Anthony
Subit, Damien
Kent, Richard W.
Estado
info:eu-repo/semantics/publishedVersion
Metadatos
Mostrar el registro completo del ítem
Mostrar METS del ítem
Ver registro en CKH

Refworks Export

Resumen
 
 
Objective: The objectives of this study were to examine the axial response of the clavicle under quasistatic compressions replicating the body boundary conditions and to quantify the sensitivity of finite element predicted fracture in the clavicle to several parameters. Methods: Clavicles were harvested from 14 donors (age range 14 56 years). Quasistatic axial compression tests were performed using a custom rig designed to replicate in situ boundary conditions. Prior to testing, high-resolution computed tomography (CT) scans were taken of each clavicle. From those images, finite element models were constructed. Factors varied parametrically included the density used to threshold cortical bone in the CT scans, the presence of trabecular bone, the mesh density, Young's modulus, the maximum stress, and the element type (shell vs. solid, triangular vs. quadrilateral surface elements). Results: The experiments revealed significant variability in the peak force (2.41 ± 0.72 kN) and displacement to peak force (4.9 ± 1.1 mm), with age (p < .05) and with some geometrical traits of the specimens. In the finite element models, the failure force and location were moderately dependent upon the Young's modulus. The fracture force was highly sensitive to the yield stress (80 110 MPa). Conclusion: Neither fracture location nor force was strongly dependent on mesh density as long as the element size was less than 5 × 5 mm2. Both the fracture location and force were strongly dependent upon the threshold density used to define the thickness of the cortical shell.
 
URI
10.1080/15389581003709902
A parametric study of hard tissue injury prediction using finite elements: consideration of geometric complexity, subfailure material properties, CT-thresholding and element characteristics
Tipo de Actividad
Artículos en revistas
ISSN
1538-9588
Materias/ categorías / ODS
Instituto de Investigación Tecnológica (IIT)
Palabras Clave

Finite element modeling, Fracture prediction, Clavicle, Side impact, Sensitivity study
Colecciones
  • Artículos

Repositorio de la Universidad Pontificia Comillas copyright © 2015  Desarrollado con DSpace Software
Contacto | Sugerencias
 

 

Búsqueda semántica (CKH Explorer)


Listar

Todo DSpaceComunidades & ColeccionesPor fecha de publicaciónAutoresTítulosMateriasPor DirectorPor tipoEsta colecciónPor fecha de publicaciónAutoresTítulosMateriasPor DirectorPor tipo

Mi cuenta

AccederRegistro

Repositorio de la Universidad Pontificia Comillas copyright © 2015  Desarrollado con DSpace Software
Contacto | Sugerencias