Relación entre valores de fuerza en flexión plantar de tobillo y actividad eléctrica en gastrocnemios
dc.contributor.advisor | Pérez Mallada, Néstor | |
dc.contributor.advisor | París Zamora, Irene | |
dc.contributor.author | Gamero Morales, Gema | |
dc.contributor.other | Universidad Pontificia Comillas, Escuela Universiaria de Enfermería Y Fisioterapia | es_ES |
dc.date.accessioned | 2018-04-17T11:44:55Z | |
dc.date.available | 2018-04-17T11:44:55Z | |
dc.date.issued | 2016 | |
dc.identifier.uri | http://hdl.handle.net/11531/26547 | |
dc.description | Titulación::Postgrado::Máster Universitario en Biomecánica y Fisioterapia Deportiva | es_ES |
dc.description.abstract | En biomecánica, la fuerza es medible gracias a la cinética y a la cinemática. El dinamómetro a través del método isocinético es uno de los más utilizados para registrar la fuerza muscular con datos objetivos y la electromiografía de superficie para recoger la actividad eléctrica de músculos superficiales. Objetivos: Obtener datos de normalidad con test cinéticos y cinemáticos en sujetos sanos en el movimiento del cuerpo humano, por rangos de edad, sexo, actividad deportiva y características antropométricas, tras la aplicación de técnicas de fisioterapia deportiva. Los objetivos específicos se resumen en correlacionar los datos de fuerza máxima y submáxima en flexión plantar de tobillo a 90º con los datos de electromiografía de superficie en gemelo medial y gemelo lateral. Se hace la recogida de datos según cada pareja de variables Hipótesis: Los valores de fuerza isométrica máxima y submáxima obtenidos y los valores de actividad eléctrica en gastrocnemios se relacionan linealmente de manera que al realizar la flexión plantar de tobillo a 90º, cuando aumenta o disminuye la fuerza también aumenta o disminuye la actividad eléctrica en el músculo. Metodología: El presente proyecto de investigación corresponde a un estudio observacional, descriptivo, con un solo grupo de sujetos donde el tipo de muestreo ha sido intencional o por conveniencia. La población diana son sujetos de entre 18 y 60 años definida por unos criterios de inclusión y de exclusión. Resultados: Tan solo las parejas de variables Fmax y RMS_GG t (-0,340), Fsub y rms_gl (normalizados) t (-0,322) y Fsub y rms_gg (en bruto) t (-0,211) obtuvieron datos significativos, pero en ningún caso podemos decir que existen relaciones lineales ya que al realizar el Coeficiente de Correlación de Pearson ninguna pareja de variables obtuvo un coeficiente r mayor que el valor crítico r = 0,367. Conclusiones: Las variables escogidas para el presente estudio, fuerza (dinamometría) y electromiografía de superficie (RMS de la señal electromiográfica) no se pueden predecir una respecto a la otra, podemos decir que, por lo tanto, las variables se comportan de manera independiente. | es_ES |
dc.description.abstract | Biomechanics, strength is measurable by the kinetics and kinematics. The dynamometer isokinetic through method is one of the most used to record muscle strength with objective data and surface electromyography to collect the electrical activity of surface muscles. Objectives: To obtain normal data with kinetic and kinematic test in healthy subjects in the movement of the human body, by age, sex, sport and anthropometric characteristics, following the application of sports physiotherapy techniques. Specific objectives are summarized if the data correlate maximum strength and submaximal ankle plantar flexion 90 ° with surface electromyography data in medial and lateral gastrocnemius. The data collection is done by each pair of variables. Hypothesis: The values of maximal isometric strength and submaximal obtained and the values of electrical activity in gastrocnemius are linearly related so that when performing plantar flexion ankle at 90 degrees, when increases or decreases the force also increases or decreases the electrical activity in the muscle. Methodology: This research project corresponds to an observational, descriptive study, with one group of subjects where the type of sampling was intentional or convenience. The target population are subjects between 18 and 60 defined by criteria of inclusion and exclusion. Results: Only couples variables Fmax and RMS_GG t (-0.340), and rms_gl Fsub (standarized) t (-0.322) and fsub and rms_gg (raw) t (-0.211) obtained significant data, but in no case can say that there are linear relationships since executing the Pearson Correlation coefficient any pair of variables obtained a coefficient r greater than the critical value r = 0.367. Conclusions: The variables chosen for this study, strength (dynamometer) and surface electromyography (RMS electromyographic signal) can not be predicted with respect to each other, we can say that, therefore, the variables behave independently. | es_ES |
dc.format.mimetype | application/pdf | es_ES |
dc.language.iso | es | es_ES |
dc.subject | UNESCO::32 Medicina::3213 Cirugía::321311 Fisioterapia | es_ES |
dc.subject | UNESCO::24 Ciencias de la vida::2402 Antropología física::240203 Antropometría y antropología forense | es_ES |
dc.subject | UNESCO::24 Ciencias de la vida::2411 Fisiología humana::241106 Fisiología del ejercicio | es_ES |
dc.subject | UNESCO::24 Ciencias de la vida::2411 Fisiología humana::241110 Fisiología del músculo | es_ES |
dc.title | Relación entre valores de fuerza en flexión plantar de tobillo y actividad eléctrica en gastrocnemios | es_ES |
dc.type | info:eu-repo/semantics/masterThesis | es_ES |
dc.rights.accessRights | info:eu-repo/semantics/closedAccess | es_ES |
dc.keywords | Contracción Isométrica, Fuerza dinamométrica, Electromiografía | es_ES |
dc.keywords | Isometric contraction, Muscle Strength Dynamometer, Electromyography | es_ES |