Comparativa entre las medidas realizadas por el Centro Nacional de Metrología y las obtenidas por TC con protocolo de hueso

Thumbnail
Ver/
Proyecto Fin de Máster (2.309Mb)
Autorización (568.2Kb)
Fecha
2016
Autor
Pedraza Carballo, Mª Gema
Director/Coordinador
París Zamora, Irene
Pérez Mallada, Néstor
Saenz Nuño, María Ana
Metadatos
Mostrar el registro completo del ítem
Mostrar METS del ítem
Ver registro en CKH

Refworks Export

Resumen
ANTECEDENTES: Este trabajo entra a formar parte de un estudio multidisciplinario integrado por ingeniería, biología, medicina, física y por su puesto fisioterapia, que pretende dar al ámbito de la salud la importancia de la trazabilidad metrólogica que se debe y que hasta ahora, no se ha dado. Son pocos los estudios que, a este respecto, intentan verificar y dar validez a las medidas que dan base a la ciencia médica. Para ello se elige la modalidad de tomografía computarizada (TC) por ser actualmente una de las modalidades radiológicas con más indicaciones para la valoración del tejido óseo y obtención de medidas con uso clínico. OBJETIVOS: comparar medidas obtenidas con la TC con unas medidas de referencia obtenidas en FREMAP y acreditado por el CEM para verificar su valor. METODOLOGÍA: Estudio pionero, observacional, cuantitativo y transversal, realizado en el Hospital Universitario de Fuenlabrada, que obtiene medidas realizadas sobre una imagen de un patrón de estructura ósea y marcadores metálicos y obtenidas mediante la modalidad radiológica de TC con protocolo específico de hueso Se realizan distintas adquisiciones de imágenes en función de la posición del patrón en la mesa de la TC y del apoyo sobre distintos planos. Para el estudio estadístico se selecciona las medidas de mayor frecuencia y se realiza un estudio descriptivo e inferencial y de comparación de medias entre las medidas resultantes y las de referencia con la T de Student. CONCLUSIONES: No existen variaciones estadísticas significativas entre las medidas obtenidas por TC y las dadas por el CEM. No existen variaciones estadísticas significativas en función de la posición de mesa y apoyo de distintos planos.
 
INTRODUCTION: This project becomes part of a team of this multidisciplinary study, integrated by: engineering, biology, medicine, physics and of course physiotherapy, which aims to give to the health field the importance that metrological traceability should have, and has not until now. There are few studies, in this regard, trying to verify and validate the measures, which give base to the medical science. Because of that computed tomography (TC) modality has been chosen, for being currently one of the radiologic modalities with more indications for the evaluation of bone tissue and obtaining measurements with clinical use. OBJETIVES: compare measurements obtained with TC with the reference measurements obtained in FREMAP and accredited by the CEM to verify its value. METHODOLOGY: Pioneer, cross-sectional observational and quantitative study conducted at the University Hospital of Fuenlabrada, which compares measurements made over an image of a pattern of bone structure and metal markers and obtained by the TC radiologic modality with a specific protocol bone, different image acquisitions are made depending on the position of the pattern on the TC table and the position on various planes. For the statistical study, measures which appear more often have been selected and is performed a descriptive and inferential study and the comparison of means between the resulting measurements and the reference ones with T-Student test. CONCLUSIONS: No statistically significant variations exist between the measurements obtained by TC and those given by the CEM. There are no statistically significant variations depending on the position nor on the table nor on different planes.
 
URI
http://hdl.handle.net/11531/26646
Trabajo Fin de Máster
Comparativa entre las medidas realizadas por el Centro Nacional de Metrología y las obtenidas por TC con protocolo de hueso
Titulación / Programa
Titulación::Postgrado::Máster Universitario en Biomecánica y Fisioterapia Deportiva
Materias/ UNESCO
UNESCO::32 Medicina::3213 Cirugía::321311 Fisioterapia
UNESCO::24 Ciencias de la vida::2402 Antropología física::240203 Antropometría y antropología forense
UNESCO::32 Medicina::3201 Ciencias clínicas::320111 Radiología
Palabras Clave
Tomografía Computarizada (TC), Patrón, Medidas
Computed tomography, Standard, Measures
Colecciones
  • H78 -Trabajos Fin de Máster

Repositorio de la Universidad Pontificia Comillas copyright © 2015  Desarrollado con DSpace Software
Contacto | Sugerencias
 

 

Búsqueda semántica (CKH Explorer)


Listar

Todo DSpaceComunidades & ColeccionesPor fecha de publicaciónAutoresTítulosMateriasPor DirectorPor tipoEsta colecciónPor fecha de publicaciónAutoresTítulosMateriasPor DirectorPor tipo

Mi cuenta

AccederRegistro

Repositorio de la Universidad Pontificia Comillas copyright © 2015  Desarrollado con DSpace Software
Contacto | Sugerencias