Mostrar el registro sencillo del ítem

dc.contributor.advisorPeña Alonso, Maria Rosa
dc.contributor.authorRuiz de Arcaute Vélez de Mendizábal, Celia
dc.contributor.otherUniversidad Pontificia Comillas, Escuela Técnica Superior de Ingeniería (ICAI)es_ES
dc.date.accessioned2015-09-18T09:22:55Z
dc.date.available2015-09-18T09:22:55Z
dc.date.issued2008
dc.identifier.urihttp://hdl.handle.net/11531/3036
dc.descriptionIngeniero Industriales_ES
dc.description.abstractSe trata de un proyecto de instalaciones de un edificio que consta de 172 oficinas y locales comerciales situado en la localidad madrileña de Leganes. Se han realizado las instalaciones de electricidad, climatización y Agua Caliente Sanitaria a través de un sistema de energía solar. Las oficinas están distribuidas en dos alas, cada una de ellas con 6 plantas consta de cuatro plantas de distintas dimensiones. Las dos primeras plantas tienen el doble de altura que las dos últimas, y el garaje, que tiene dos plantas, esta situado bajo el edificio por lo que consta de ventilación forzada. Para llevar a cabo la instalación eléctrica se ha analizado la previsión de cargas. Cada una de las oficinas tiene una electrificación elevada ya que tienen un sistema individualizado de aire acondicionado. Cada una de las oficinas tiene una carga de 9200W. Para los locales comerciales se ha tenido en cuenta que tienen una electrificación de lOOW por metro cuadrado, y para el garaje de 20W por metro cuadrado. A esta potencia total necesaria se ha sumado la de las zonas comunes, la piscina y los distintos equipos de los que consta un edificio: bombas, caldera ... etc. La previsión de carga total será de 1876,70 Kw. A partir de esta potencia se diseña el sistema eléctrico, este consta de diversos elementos: La acometida que es parte de la instalación de la red de distribución, y alimenta las Bases Tripolares Verticales (Cajas de protección). Su instalación se diseñara atendiendo a su trazado, al sistema de instalación y a las características de la red. Se llevaran 15 Líneas Generales de Alimentación, cada una reparte la potencia necesaria a las distintas partes del edificio y la lleva a las centralizaciones de contadores. Las centralizaciones están divididas en dos grupos diferenciados: para suministros monofásicos (viviendas) y para suministros trifásicos: servicios comunes de cada portal, servicios de comunidad, garaje y piscina. Las derivaciones individuales se inician en el embarrado general, llegando a cada una de las oficinas y locales comerciales de forma que se contabilice el consumo individualizado. Las secciones de los conductores, protecciones y canalizaciones se calculan atendiendo al Reglamento Electrotécnico de Baja Tensión.La instalación de climatización, tiene por objeto cubrir las necesidades de acondicionamiento del conjunto de este edificio. La instalación ha sido concebida de acuerdo con los siguientes criterios: mantener temperatura constante e independiente para cada una de las oficinas a climatizar, elección de un sistema que permita el uso independiente de cada zona, y conseguir un alto nivel de ahorro energético, al permitir al sistema adecuarse a las variaciones de ocupación, aportaciones caloríficas, etc. Todas las dependencias a climatizar tendrán un control individual de las unidades interiores de climatización, de esta manera se podrá controlar la temperatura de todas las dependencias de manera individual. Las necesidades a cubrir se calcularan a partir de las cargas térmicas. Se calcularán para las oficinas más desfavorables, teniendo siempre en cuenta la carga térmica sensible y la carga térmica latente. La carga sensible se compone de cargas térmicas por radiación solar a través de cristales, por transmisión y radiación a través de muros y techos exteriores, por transmisión a través de todos los demás cerramientos. La carga latente es aquella que puede ser medida por una variación de la humedad específica del local y está formada por la carga térmica latente de ocupantes y la carga latente de ventilación. Para la producción de agua caliente sanitaria, se utilizará un sistema centralizado. De esta forma produciremos ACS a partir de una caldera situada en la cubierta en la sala de calderas, y a partir de la Energía Solar Térmica (ETS) utilizando dos acumuladores de agua ya que tal y como dice el Código Técnico de Edificación, será obligatorio cubrir un porcentaje de la energía necesaria mediante paneles solares. Su aplicación es muy habitual y rentable. El tipo de instalación más apropiada, es la de circulación forzada y circuito cerrado, ya que es la indicada para grandes instalaciones y aunque necesita energía eléctrica permite buenas posibilidades de regulación de la instalación. Este tipo de instalación supone un gran ahorro económico, el combustible es gratuito y los costes de mantenimiento son bajos. Además se trata de una energía limpia e inagotable y proporciona una imagen positiva de calidad ambiental a las instalaciones de la empresa. La instalación de paneles solares para el ACS supone también preparar a la empresa a posibles fluctuaciones de los precios de la energía y limitaciones de gases de efecto invernadero. Es decir, incrementa de esta forma el margen de maniobra, lo que redundará favorablemente en su cuenta de resultados.es_ES
dc.description.abstractThis project is about the installations of a building which has 172 offices and other business properties, which is located in Leganés. The electric installations, aconditionation and the domestic hot water have already been done through a solar power system. The offices had been distributed in two different spaces. Each of them has 6 different floors, 4 of these floors have different dimensions. The first two floors have twice the height of the two last floors, and the garage, which has two floors is located undemeath the building, and that is way it has ventilation. To perform the electricity installations we have analyze the forecast. Each one of the offices use many electricity because they have there individual air conditioning systems. Each one of the offices has an electricity charge of 9200W. For the other business properties we have given them for the electricity charge lOOW per square metre, and for the garage 20W per square metre. To the total power we have add up the power from the community area, the swimming pool and the other equipment from the building, such as the boiler and other pumps. The total forecast will be 1876,70 Kw. Over this power we also design an electric system which is made up of: The assault which is part of the installation distribution net, and it sources the three poles vertical basis (protection boxes). Its installation will be designed according to its drawing, to the installation sistem and to the net characteristics. It will have 15 general source lines, each one feed the necessary power to the several parts of the bulding and it takes the power to the meters centralization. The centralizations are divided in two different groups: For one phase suplies (houses) and for three phase supplies; cornrnun servicies of each hall, cornrnunity services, garage and swimming pool. The individual deviatos will begin in the general winding, arriving to each one of the offices and comercial places accounting the individual consume. The conductor sections, protecctions, and canalizations will be calculated according to the Low Voltage Electrotecnic Standard. The object of the aconditionating installation is to cover the necessities of the whole building acconditionating. The installation has been designed according to the following criterias: For mantaining the temperature constant and independent for each office, for the selection of a sistem which allowsthe independent use for each place, and get the maximum energetic efficency, for allowing a system according to the different assistance, callorific contribution, etc. All the different parts will have an individial control of the intemal acconditionating units, with this it will be able control the temperatura of all the parts. The necessities that we will have to satisfy they will be calculated from the thermal loads. They will be calculated for the most unfovourable offices, taking into account always the thermal sensible load and thermal latent load. The sensible load is compound of the thermal charges from radiation through the cristals, for transmisions and radiation through the wall and exterior roof, by transmission through all the rest of closures. The latent load is the one that can be measure by a variation of the specific humidity in the local and it is form of the thermal latent load of the occupants and the latent load of the ventilation. To produce domestic hot water, we will use a central system, this way we will produce ACS, since the boiler located in the covered boiler room and the Solar Energy and using to water accumulations, just as it says in the Construction Code, we will have to take care of the percentage of energy needed by solar panels. It is use is regular and also worthwhile. The type of installation more appropriate is the circulating forced and closed circuit. This is the specified type to use in big installations although it needs electric energy it offers good possibilities to regular the installations. This installation, means saving a big amount of money and also free combustible. The supports cost are not very much. The energy is also clean and inexhaustible and it also gives a positive image of quality environmental to the company's installations. The installation of the Solar Panels means, preparing the company for possible fluctuations of the energy prices and limitations of the gas from the greenhouse effects. It increases the little leeway and it will benefit the account results.es_ES
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoeses_ES
dc.subject33 Ciencias tecnológicases_ES
dc.subject3313 Tecnología e ingeniería mecánicases_ES
dc.subject331326 Equipo de refrigeraciónes_ES
dc.titleInstalación eléctrica de climatización y Y A.C.S. solar de un edificio de 172 oficinas y locales comercialeses_ES
dc.typeinfo:eu-repo/semantics/bachelorThesises_ES
dc.rights.accessRightsinfo:eu-repo/semantics/closedAccesses_ES


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem