Mostrar el registro sencillo del ítem
Influencia sobre la fuerza y la activación muscular tras la aplicación de ondas de choque en la musculatura extensora de muñeca.
dc.contributor.advisor | Blanco Méndez, Ricardo | |
dc.contributor.author | Sopeña Cueto, Laura | |
dc.contributor.other | Universidad Pontificia Comillas, Escuela Universiaria de Enfermería Y Fisioterapia | es_ES |
dc.date.accessioned | 2019-10-15T08:39:19Z | |
dc.date.available | 2019-10-15T08:39:19Z | |
dc.date.issued | 2019 | |
dc.identifier.uri | http://hdl.handle.net/11531/42510 | |
dc.description | Titulación::Postgrado::Máster Universitario en Biomecánica y Fisioterapia Deportiva | es_ES |
dc.description.abstract | Antecedentes: La activación de la musculatura extensora de la muñeca es muy importante para la estabilización de la muñeca y cualquier cambio de actividad o fuerza puede afectar a la función de los miembros superiores. La terapia con ondas de choque es cada vez más utilizada en problemas musculoesqueléticos, sin embargo, existen muy pocos artículos que hablen influencia de su aplicación en la fuerza y activación muscular de la musculatura. Objetivo: Comparar los datos de fuerza y grado de activación muscular obtenidos entre dos grupos de sujetos tras la aplicación de ondas de choque radiales vs estímulo placebo sobre la musculatura extensora de muñeca dominante. Diseño: Se trata de un estudio cuantitativo, analítico experimental, prospectivo en el que se realiza un muestreo no probabilístico por conveniencia para obtener los sujetos del estudio, distribuidos de forma aleatoria en dos grupos de intervención. Metodología: Se distribuyen los sujetos en dos grupos, el experimental, al que se le aplican ondas de choque radiales y el grupo control al que se le aplica un placebo de ondas de choque. En ambos se miden pre y post-intervención las variables fuerza máxima isocinética, isocinética mediante dinamometría computarizada y el grado máximo de activación muscular de extensión de muñeca utilizando EMGs. Conclusión: Se obtienen diferencias significativas en la fuerza isométrica de extensión de muñeca dominante entre el grupo experimental y control tras la aplicación de ondas de choque. Mientras que no se obtienen diferencias significativas en la fuerza isocinética ni en la EMGs. | es_ES |
dc.description.abstract | Background: The activation of the wrist extensor musculature is very important for the stabilization of the wrist and any change in activity or strength can affect the function of the upper limbs. Therapy with shock waves is increasingly used in musculoskeletal problems, however, there are very few articles that speak of its influence on the strength and muscle activation of the musculature. Objective: To compare the data of strength and degree of muscle activation obtained between two groups of subjects after the application of radial shock waves vs placebo stimulation on the dominant wrist extensor musculature. Design: This is a quantitative, experimental, prospective analytical study in which a non-probabilistic sampling is carried out for convenience to obtain the subjects of the study, randomly distributed in two intervention groups. Methodology: The subjects are divided into two groups, the experimental group, to which radial shock waves are applied and the control group to which a placebo is applied. In both, the variables isokinetic, isokinetic maximal force by computer dynamometer and the maximum degree of wrist extension muscle activation using EMGs are measured pre and post-intervention. Conclusion: Significant differences are obtained in the isometric strength of dominant wrist extension between the experimental group and control after the application of shock waves. While no significant differences are obtained in the isokinetic force nor in the EMGs. | es_ES |
dc.format.mimetype | application/pdf | es_ES |
dc.language.iso | es | es_ES |
dc.subject | UNESCO::32 Medicina::3213 Cirugía::321311 Fisioterapia | es_ES |
dc.title | Influencia sobre la fuerza y la activación muscular tras la aplicación de ondas de choque en la musculatura extensora de muñeca. | es_ES |
dc.type | info:eu-repo/semantics/masterThesis | es_ES |
dc.rights.accessRights | info:eu-repo/semantics/closedAccess | es_ES |
dc.keywords | Ondas de choque, Fuerza isométrica, Fuerza isocinética, Electromiografía de superficie, Muñeca | es_ES |
dc.keywords | Shock waves, Isometric strenght, Isokinetic strenght, Surface electromyography, Wrist | es_ES |