Coordinated control in VSC-HVDC Multi- terminal systems to improve transient stability: the impact of communication latency

Thumbnail
Ver/
IIT-19-094A.pdf (1.737Mb)
Fecha
2019-10-01
Autor
Renedo Anglada, Javier
García Cerrada, Aurelio
Rouco Rodríguez, Luis
Sigrist, Lukas
Estado
info:eu-repo/semantics/publishedVersion
Plumx metric
Metadatos
Mostrar el registro completo del ítem
Mostrar METS del ítem
Ver registro en CKH

Refworks Export

Resumen
 
 
Power transmission is the main purpose of high voltage direct current systems based on voltage source converters (VSC-HVDC). Nevertheless, this type of system can also help to improve transient stability by implementing suitable supplementary controllers. Previous work proposed active- (P) and reactive-power (Q) control strategies in VSC-HVDC multi-terminal systems (VSC-MTDC, for short) to improve transient stability, producing significant improvements. In those strategies, each VSC station of the MTDC system compares its frequency measurement with the average of the frequencies measured by all converter stations of the MTDC system (weighted-average frequency, WAF) in order to modulate its own P and Q injections. Hence, a communication system is required. This paper presents a detailed analysis of the impact of communication latency on the performance of those control strategies. The communication delays have been modelled using a Padé’s approximation and their impact on the performance of the control strategies have been assessed by means of time-domain simulation in PSSE. The effect of the control strategies on transient stability has been quantified with the critical clearing time (CCT) of a set of faults. Results show that the control strategies analysed present good results for realistic values of communication delays.
 
URI
https:doi.org10.3390en12193638
DOI
10.3390/en12193638
Coordinated control in VSC-HVDC Multi- terminal systems to improve transient stability: the impact of communication latency
Tipo de Actividad
Artículos en revistas
ISSN
1996-1073
Materias/ categorías / ODS
Instituto de Investigación Tecnológica (IIT)
Palabras Clave

power systems; high voltage direct current (HVDC) transmission; HVDC systems based on voltage source converters (VSC-HVDC); multi-terminal; transient stability; control strategies; communication latency
Colecciones
  • Artículos

Repositorio de la Universidad Pontificia Comillas copyright © 2015  Desarrollado con DSpace Software
Contacto | Sugerencias
 

 

Búsqueda semántica (CKH Explorer)


Listar

Todo DSpaceComunidades & ColeccionesPor fecha de publicaciónAutoresTítulosMateriasPor DirectorPor tipoEsta colecciónPor fecha de publicaciónAutoresTítulosMateriasPor DirectorPor tipo

Mi cuenta

AccederRegistro

Repositorio de la Universidad Pontificia Comillas copyright © 2015  Desarrollado con DSpace Software
Contacto | Sugerencias