Security-constrained optimal power and natural-gas flow
Fecha
2014-07-01Estado
info:eu-repo/semantics/publishedVersionMetadatos
Mostrar el registro completo del ítemResumen
Continuous liberalization and interconnection of energy markets worldwide has raised concerns about the inherent interdependency between primary energy supply and electric systems. With the growing interaction among energy carriers, limitations on the fuel delivery are becoming increasingly relevant to the operation of power systems. This paper contributes with a novel formulation of a mixed-integer linear programing (MILP) security-constrained optimal power and gas flow. To this end, an iterative methodology, based on development of linear sensitivity factors, determines the stabilized post-contingency condition of the integrated network. The proposed model allows system operators not only to perform security analysis but also to adjust in advance state variables of the integrated system optimally and fast, so that n-1 contingencies do not result in violations. Case studies integrate the IEEE 24-bus system and a modified Belgian high-calorific gas network for analyzing the performance of the formulation and solution methodology. Continuous liberalization and interconnection of energy markets worldwide has raised concerns about the inherent interdependency between primary energy supply and electric systems. With the growing interaction among energy carriers, limitations on the fuel delivery are becoming increasingly relevant to the operation of power systems. This paper contributes with a novel formulation of a mixed-integer linear programing (MILP) security-constrained optimal power and gas flow. To this end, an iterative methodology, based on development of linear sensitivity factors, determines the stabilized post-contingency condition of the integrated network. The proposed model allows system operators not only to perform security analysis but also to adjust in advance state variables of the integrated system optimally and fast, so that n-1 contingencies do not result in violations. Case studies integrate the IEEE 24-bus system and a modified Belgian high-calorific gas network for analyzing the performance of the formulation and solution methodology.
Security-constrained optimal power and natural-gas flow
Tipo de Actividad
Artículos en revistasISSN
0885-8950Materias/ UNESCO
33 Ciencias tecnológicas3311 Tecnología de la instrumentación
331102 Ingeniería de control
3321 Tecnología del carbón y del petróleo
332107 Gas natural
Materias/ categorías / ODS
Instituto de Investigación Tecnológica (IIT)Palabras Clave
security constrained, optimal power flow, security analysis, natural gas networks, integrated energy systems.security constrained, optimal power flow, security analysis, natural gas networks, integrated energy systems.


