Heuristic algorithm for photoplethysmographic heart rate tracking during maximal exercise test

Thumbnail
View/Open
IIT-12-059A.pdf (448.8Kb)
Date
01/07/2012
Author
López-Silva, Sonnia María
Giannetti, Romano
Dotor Castilla, María Luisa
Silveira, J.
Golmayo Fernández, Dolores
Miguel-Tobal, Francisco
Bilbao Monasterio, Amaya
Galindo Canales, Mercedes
Martín Escudero, Pilar
Estado
info:eu-repo/semantics/publishedVersion
Metadata
Show full item record
Mostrar METS del ítem
Ver registro en CKH

Refworks Export

Abstract
 
 
Photoplethysmography (PPG) is a non-invasive optical technique that can be used to quantify the arterial blood pulse rate. Signal corruption by motion artifacts limits the practical accuracy and applicability of instruments for monitoring pulse rate during intense physical exercise. This study develops and validates an algorithm, which is based on linear filtering and frequency-domain and heuristic analyses, for extracting the heart rate from a PPG signal in the presence of severe motion artifacts. The basis of the hearth beat frequency selection is the observed high harmonic content of movement artifact signals with respect to the PPG-derived heartbeat. The algorithm, implemented in an experimental PPG measurement device, is developed by analyzing a set of PPG data recorded from a group of athletes exercising on a treadmill. An extensive set of tests is carried out during maximal exercise tests on a treadmill to validate the proposed algorithm by comparison with a reference electrocardiography measurement system. The Bland-Altman method is used to compare and evaluate PPG signals. The accuracy of the heartbeat measurement is better than ± 6.5 beats per minute (bpm) ( = 4.2 %) even under maximal exercise conditions.
 
URI
10.5405/jmbe.898
Heuristic algorithm for photoplethysmographic heart rate tracking during maximal exercise test
Tipo de Actividad
Artículos en revistas
ISSN
1609-0985
Materias/ categorías / ODS
Instituto de Investigación Tecnológica (IIT)
Palabras Clave

Biomedical signal processing, photoplethysmography (PPG), motion artifact, heart rate
Collections
  • Artículos

Repositorio de la Universidad Pontificia Comillas copyright © 2015  Desarrollado con DSpace Software
Contact Us | Send Feedback
 

 

Búsqueda semántica (CKH Explorer)


Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsxmlui.ArtifactBrowser.Navigation.browse_advisorxmlui.ArtifactBrowser.Navigation.browse_typeThis CollectionBy Issue DateAuthorsTitlesSubjectsxmlui.ArtifactBrowser.Navigation.browse_advisorxmlui.ArtifactBrowser.Navigation.browse_type

My Account

LoginRegister

Repositorio de la Universidad Pontificia Comillas copyright © 2015  Desarrollado con DSpace Software
Contact Us | Send Feedback