• English
    • español
  • español 
    • English
    • español
  • Login
Ver ítem 
  •   Repositorio Comillas
  • 2.- Investigación
  • Artículos
  • Ver ítem
  •   Repositorio Comillas
  • 2.- Investigación
  • Artículos
  • Ver ítem
JavaScript is disabled for your browser. Some features of this site may not work without it.

Demand response in an isolated system with high wind integration

Thumbnail
Ver/
IIT-11-095A.pdf (698.1Kb)
Fecha
01/02/2012
Autor
Dietrich, Kristin
Latorre Canteli, Jesús María
Olmos Camacho, Luis
Ramos Galán, Andrés
Estado
info:eu-repo/semantics/publishedVersion
Metadatos
Mostrar el registro completo del ítem
Mostrar METS del ítem
Ver registro en CKH

Refworks Export

Resumen
 
 
Growing load factors in winter and summer peaks are a serious problem faced by the Spanish electric energy system. This has led to the extensive use of peak load plants and thus to higher costs for the whole system. Wind energy represents a strongly increasing percentage of overall electricity production, but wind normally does not follow the typical demand profile. As generation flexibility is limited due to technical restrictions, and in absence of large energy storages, the other side of the equilibrium generation-demand has to react. Demand Side Management measures intend to adapt the demand profile to the situation in the system. In this paper, the operation of an electric system with high wind penetration is modeled by means of a unit commitment problem. Demand shifting and peak shaving are considered in this operation problem. Demand shifting is modeled in two different ways. Firstly the system operator controls the shift of demand; secondly each consumer decides its reaction to prices depending on its elasticity. The model is applied to the isolated power system of Gran Canaria. The impact of an increased installed wind capacity on operation and the cost savings resulting from the introduction of responsive demand are assessed. Furthermore, results from the different implemented demand response options are compared.
 
URI
http://hdl.handle.net/11531/5057
Demand response in an isolated system with high wind integration
Tipo de Actividad
Artículos en revistas
ISSN
0885-8950
Palabras Clave

Wind power generation, Large-scale integration, Load management, Power system modeling
Colecciones
  • Artículos

Repositorio de la Universidad Pontificia Comillas copyright © 2015  Desarrollado con DSpace Software
Contacto | Sugerencias
 

 

Búsqueda semántica (CKH Explorer)


Listar

Repositorio ComillasComunidades & ColeccionesPor fecha de publicaciónAutoresTítulosMateriasEsta colecciónPor fecha de publicaciónAutoresTítulosMaterias

Mi cuenta

AccederRegistro

Repositorio de la Universidad Pontificia Comillas copyright © 2015  Desarrollado con DSpace Software
Contacto | Sugerencias