dc.description.abstractLa elección de la tensión de una línea está caracterizada por multitud de parámetros, siendo una de las características principales y con mayor relevancia de las líneas de transporte y distribución. Existen multitud de fenómenos que dependen del nivel de tensión de la línea y que es importante determinar y tener en cuenta su aparición, ya que, en algunos casos, esta puede no favorecer el transporte de potencia. En este documento se ha querido plasmar la importancia que tiene la elección del nivel de tensión en una línea eléctrica aérea. Para ello, se han analizado los fenómenos que han tenido lugar en dos líneas con mismo un trazado y características, pero dos niveles de tensión distintos: 66 kV y 400 kV. Ambas líneas se sitúan en Caparacena, en la provincia de Málaga, y se ha de decidir qué tensión reporta menores costes de construcción, afecta menos a la seguridad de las personas y es más eficiente en términos de transporte de potencia. Se tuvieron en cuenta para el desarrollo de este proyecto parámetros tanto eléctricos como mecánicos, la influencia de los campos electromagnéticos y el coste de construcción de los materiales, el montaje y la obra civil de ambas líneas.es-ES
dc.description.abstractThe choice of the voltage of a line is characterized by a multitude of parameters, being one of the main and most relevant characteristics of transmission and distribution lines. There are many phenomena that depend on the voltage level of the power line and it is important to determine and take into account their occurrence, since, in some cases, this may not favor the transport of power. In this document it has been intended to show the importance of choosing the voltage level in an overhead power line. For this purpose, it has been analyzed the phenomena that have occurred in two lines with the same location and characteristics, but with two different voltage levels: 66 kV and 400 kV. Both lines are located in Caparacena, in the province of Malaga, and it has to be decided which voltage has lower construction costs, has less impact on people's safety and is more efficient in terms of power transmission. Both electrical and mechanical parameters were taken into account for the development of this project, as well as the influence of electromagnetic fields and the cost of construction of materials, assembly and civil works of both lines.en-GB
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoes-ESes_ES
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 United Stateses_ES
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/us/es_ES
dc.subject.otherKTI-electricidad (GITI-E)es_ES
dc.titleComparativa de las líneas eléctricas L/66 kV ST BÚCOR–ST Promotores Caparacena y L/400 kV ST BÚCOR–ST Promotores Caparacenaes_ES
dc.typeinfo:eu-repo/semantics/bachelorThesises_ES
dc.rights.accessRightsinfo:eu-repo/semantics/closedAccesses_ES
dc.keywordslínea aérea, nivel de tensión, fenómeno, efecto corona, caída de tensiónes-ES
dc.keywordsoverhead line, voltage, phenomena, corona, voltage dropen-GB