• English
    • español
  • English 
    • English
    • español
  • Login
View Item 
  •   Home
  • 2.- Investigación
  • Artículos
  • View Item
  •   Home
  • 2.- Investigación
  • Artículos
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Method development and validation for melamine and its derivatives in rice concentrates by liquid chromatography. Application to animal feed samples

Thumbnail
View/Open
IIT-08-088A.pdf (213.3Kb)
Date
01/10/2008
Author
Muñíz Valencia, Roberto
Ceballos Magaña, Silvia G.
Rosales Martínez, Daniel
Gonzalo Lumbreras, Raquel
Santos Montes, Ana María
Cubedo Fernández-Trapiella, Angel
Izquierdo Hornillos, Roberto
Estado
info:eu-repo/semantics/publishedVersion
Metadata
Show full item record
Mostrar METS del ítem
Ver registro en CKH

Refworks Export

Abstract
 
 
An isocratic LC method for the determination of melamine and its degradation products (ammelide, ammeline, and cyanuric acid), used to increase the apparent protein content of rice protein concentrate, has been developed. Method development involved optimization of different RP columns, aqueous mobile phases, pH, phosphate concentration, and temperature. The optimum separation of these compounds was achieved using a Luna CN column (30 degrees C), 5 mmol L(-1) sodium phosphate (pH 5.0) as mobile phase, 1 mL min(-1) flow-rate, UV absorbance-DAD detection at 220 nm, and resorcine as internal standard; this enabled separation of these compounds with baseline resolution (values in the 2.1-10.1 range) in about 8 min. Prior to HPLC, the developed sample preparation procedure consisted in a leaching process using the above mentioned mobile phase. Method validation was carried out in rice protein concentrates in accordance with the European Commission decision 2002/657/EC criteria. For this purpose, eight mandatory performance characteristics for the conventional validation approach were determined: calibration graphs, extraction efficiencies, decision limits, detection capabilities, precision (repeatability and within-laboratory reproducibility), accuracy, selectivity, and robustness. The extraction efficiencies for these compounds were in the range 99-100\% and the within-laboratory reproducibility at 1.0, 1.5, and 2.0 detection capabilities concentration levels were smaller than 5, 4, and 3\%, respectively. Finally, the proposed method was successfully applied to the analysis of other rice protein concentrates and several animal feed samples.
 
URI
http://hdl.handle.net/11531/5225
Method development and validation for melamine and its derivatives in rice concentrates by liquid chromatography. Application to animal feed samples
Tipo de Actividad
Artículos en revistas
ISSN
1618-2642
Palabras Clave

Rice protein concentrate; Animal feed; Melamine; Cyanuric acid; Ammelide; Ammeline; Liquid chromatography;
Collections
  • Artículos

Repositorio de la Universidad Pontificia Comillas copyright © 2015  Desarrollado con DSpace Software
Contact Us | Send Feedback
 

 

Búsqueda semántica (CKH Explorer)


Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsxmlui.ArtifactBrowser.Navigation.browse_advisorxmlui.ArtifactBrowser.Navigation.browse_typeThis CollectionBy Issue DateAuthorsTitlesSubjectsxmlui.ArtifactBrowser.Navigation.browse_advisorxmlui.ArtifactBrowser.Navigation.browse_type

My Account

LoginRegister

Repositorio de la Universidad Pontificia Comillas copyright © 2015  Desarrollado con DSpace Software
Contact Us | Send Feedback