Mostrar el registro sencillo del ítem

dc.contributor.authorMuñíz Valencia, Robertoes-ES
dc.contributor.authorGonzalo Lumbreras, Raqueles-ES
dc.contributor.authorSantos Montes, Ana Maríaes-ES
dc.contributor.authorIzquierdo Hornillos, Robertoes-ES
dc.date.accessioned2016-01-15T11:19:01Z
dc.date.available2016-01-15T11:19:01Z
dc.date.issued01/02/2008es_ES
dc.identifier.issn1615-9306es_ES
dc.identifier.urihttp://hdl.handle.net/11531/5255
dc.descriptionArtículos en revistases_ES
dc.description.abstractes-ES
dc.description.abstractSeveral isocratic separations for the determination of 20 steroids (STER) in animal feeding water samples (AFWS) from drinking-trough by LC using a mobile phase ACN/H(2)O (35:65 v/v) and different RP columns (Hypersil C18, Gemini C18 (GM), Purospher Star C18, Synergi Max C12, and Synergi Fusion) and UV detection were obtained. The elution order was the same: a first group of corticoids (CC) was early eluted, a second group of CC and anabolics (AAS) exhibited intermediate retention, and a third group constituted by AAS was strongly retained. To improve the separation performances of the isocratic separations an ACN gradient elution optimization was carried out for each column. The most satisfactory results were obtained using a Purospher column which allowed the separation of 19 STER in an analysis time close to 26 min. After sample preparation using SPE, method validation was performed in an AFWS spiked with STER according to the EC decision criteria established for quantitative screening methods. For this purpose calibration graphs, extraction efficiencies, decision limits, detection capabilities, precision (repeatability and within-laboratory reproducibility), accuracy, selectivity, and robustness were evaluated. The proposed method was applied to other AFWS with satisfactory results.en-GB
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoen-GBes_ES
dc.rightses_ES
dc.rights.uries_ES
dc.sourceRevista: Journal of Separation Science, Periodo: 1, Volumen: 31, Número: 2, Página inicial: 219, Página final: 28es_ES
dc.titleQuantitative screening for steroids in animal feeding water using reversed phase LC with gradient elutiones_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.description.versioninfo:eu-repo/semantics/publishedVersiones_ES
dc.rights.accessRightsinfo:eu-repo/semantics/restrictedAccesses_ES
dc.keywordses-ES
dc.keywordsAnimal feeding water; Gradient elution; Growth promoting agents; LC; Steroids;en-GB


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

  • Artículos
    Artículos de revista, capítulos de libro y contribuciones en congresos publicadas.

Mostrar el registro sencillo del ítem