• English
    • español
  • español 
    • English
    • español
  • Login
Ver ítem 
  •   DSpace Principal
  • 2.- Investigación
  • Artículos
  • Ver ítem
  •   DSpace Principal
  • 2.- Investigación
  • Artículos
  • Ver ítem
JavaScript is disabled for your browser. Some features of this site may not work without it.

Comparison of the performance of different reversed-phase columns for liquid chromatography separation of 11 pollutant phenols

Thumbnail
Ver/
IIT-07-057A.pdf (594.8Kb)
Fecha
01/03/2007
Autor
Cledera Castro, Mª del Mar
Santos Montes, Ana María
Izquierdo Hornillos, Roberto
Gonzalo Lumbreras, Raquel
Estado
info:eu-repo/semantics/publishedVersion
Plumx metric
Metadatos
Mostrar el registro completo del ítem
Mostrar METS del ítem
Ver registro en CKH

Refworks Export

Resumen
 
 
A systematic optimization of the HPLC separation of a mixture containing 11 pollu- tant phenols (PPs) using a Hypersil ODS (250mm64.6 mm, 5 lm) column and UV- DAD detection has been carried out. The binary mobile phases used were obtained by mixing 50mM phosphate (pH = 3.0) and methanol, ACN, or THF as organic modi- fiers. After selecting ACN as an organic modifier, the effects of pH and temperature on PPs separation were studied. A mobile phase of 50mM acetate (pH = 5.0)-ACN (60:40 v/v) at 508C allowed the separation of 11 phenols but not to baseline in 17 min. To improve the performance of this separation, the following RP columns were tested: Luna C18 (2), Purospher C18, Synergi C12, Synergi Fusion C18, Gemini C18, Luna Cyano, Lichrospher C8, and Envirosep-PP (polymeric). In all the cases, the performance (analysis time, retention, selectivity, resolution, asymmetry factors, and efficiency) was evaluated. A further reoptimization of the mobile phase was car- ried out for all the columns by studying the ACN content and pH, with the aim of improving the above-mentioned separations and selecting the most suitable one for PPs analysis.
 
URI
http://hdl.handle.net/11531/5286
DOI
10.1002/jssc.200600301
Comparison of the performance of different reversed-phase columns for liquid chromatography separation of 11 pollutant phenols
Tipo de Actividad
Artículos en revistas
ISSN
1615-9306
Materias/ categorías / ODS
Instituto de Investigación Tecnológica (IIT)
Palabras Clave

Pollutant phenols / Reversed-phase columns
Colecciones
  • Artículos

Repositorio de la Universidad Pontificia Comillas copyright © 2015  Desarrollado con DSpace Software
Contacto | Sugerencias
 

 

Búsqueda semántica (CKH Explorer)


Listar

Todo DSpaceComunidades & ColeccionesPor fecha de publicaciónAutoresTítulosMateriasPor DirectorPor tipoEsta colecciónPor fecha de publicaciónAutoresTítulosMateriasPor DirectorPor tipo

Mi cuenta

AccederRegistro

Repositorio de la Universidad Pontificia Comillas copyright © 2015  Desarrollado con DSpace Software
Contacto | Sugerencias