Mostrar el registro sencillo del ítem

dc.contributor.authorBravo Sánchez, Alfredoes-ES
dc.contributor.authorAbian Vicen, Pabloes-ES
dc.contributor.authorSánchez Infante, Jorgees-ES
dc.contributor.authorEsteban García, Paulaes-ES
dc.contributor.authorJiménez Díaz, Fernandoes-ES
dc.contributor.authorAbian Vicen, Javieres-ES
dc.date.accessioned2021-05-11T09:34:16Z
dc.date.available2021-05-11T09:34:16Z
dc.date.issued06/05/2021es_ES
dc.identifier.issn1424-8220es_ES
dc.identifier.urihttps://doi.org/10.3390/ s21093213es_ES
dc.identifier.urihttp://hdl.handle.net/11531/55641
dc.descriptionArtículos en revistases_ES
dc.description.abstract.es-ES
dc.description.abstractThe objective of this study was to evaluate the reliability of four methods of assessing vastus lateralis (VL) stiffness, and to describe the influence of structural characteristics on them. The stiffness of the dominant lower-limb’s VL was evaluated in 53 healthy participants (28.4 9.1 years) with shear wave elastography (SWE), strain elastography (SE), myotonometry and tensiomyography (TMG). The SWE, SE and myotonometry were performed at 50%, and TMG was assessed at 30%, of the length from the upper pole of the patella to the greater trochanter. The thickness of the VL, adipose tissue and superficial connective tissue was also measured with ultrasound. Three repeated measurements were acquired to assess reliability, using intraclass correlation coefficients (ICC). Pearson’s correlation coefficients were calculated to determine the relationships between methodologic assessments and between structural characteristics and stiffness assessments of the VL. Myotonometry (ICC = 0.93; 95%-CI = 0.89,0.96) and TMG (ICC = 0.89; 95%-CI = 0.82,0.94) showed excellent inter-day reliability whereas with SWE (ICC = 0.62; 95%-CI = 0.41,0.77) and SE (ICC = 0.71; 95%-CI = 0.57,0.81) reliability was moderate. Significant correlations were found between myotonometry and VL thickness (r = 0.361; p = 0.008), adipose tissue thickness (r = 􀀀0.459; p = 0.001) and superficial connective tissue thickness (r = 0.340; p = 0.013). Myotonometry and TMG showed the best reliability values, although myotonometry stiffness values were influenced by the structural variables of the supra-adjacent tissue.en-GB
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoes-ESes_ES
dc.rightsCreative Commons Reconocimiento-NoComercial-SinObraDerivada Españaes_ES
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/es_ES
dc.sourceRevista: Sensors, Periodo: 1, Volumen: 21, Número: , Página inicial: 1, Página final: 13es_ES
dc.titleObjective assessment of regional stiffness in vastus lateralis with different measurement methods: a reliability studyes_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.description.versioninfo:eu-repo/semantics/publishedVersiones_ES
dc.rights.holderes_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.keywords.es-ES
dc.keywordsshear wave elastography; strain elastography; MyotonPRO; tensiomyography; mechanical propertiesen-GB


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

  • Artículos
    Artículos de revista, capítulos de libro y contribuciones en congresos publicadas.

Mostrar el registro sencillo del ítem

Creative Commons Reconocimiento-NoComercial-SinObraDerivada España
Excepto si se señala otra cosa, la licencia del ítem se describe como Creative Commons Reconocimiento-NoComercial-SinObraDerivada España