A least-squares approach to estimate Lagrange multipliers in a combined method to voltages collapse detection

Thumbnail
View/Open
IIT-03-025A.pdf (146.6Kb)
Date
2003-07-03
Author
Echavarren Cerezo, Francisco
Lobato Miguélez, Enrique
Rouco Rodríguez, Luis
Navarrete Fernández, María Isabel
Casanova Lafarga, Rosa
López, G.
Cacho, F.
Pézic, M.
Estado
info:eu-repo/semantics/publishedVersion
Metadata
Show full item record
Mostrar METS del ítem
Ver registro en CKH

Refworks Export

Abstract
 
 
Voltage stability is concerned with the ability of a power system to maintain acceptable voltages at all buses. A measure of the power system voltage stability is the distance to the saddle node bifurcation of the power flow equations, which is called the load margin. Two approaches are widely used to compute the critical load margin: Continuation and Optimization. The first approach uses tangent vectors of the power flow equations to determine the saddle node bifurcation, whereas the second approach formulates it as a non-linear optimization problem. This paper reviews both algorithms, and proposes a method to combine both techniques, obtaining the load margin-voltages curves, and the sensitivities of the critical load margin with respect to the active and reactive power dispatch. Starting from an approximation of the saddle node bifurcation, calculated by continuation method, a least-squares problem is formulated to obtain an approximation of the Lagrange multipliers. This approximation will be used as starting point on critical load margin calculation by optimization method. The performance of the method is illustrated with the CIGRE 32-buses test system.
 
URI
http://hdl.handle.net/11531/5694
A least-squares approach to estimate Lagrange multipliers in a combined method to voltages collapse detection
Tipo de Actividad
Capítulos en libros
Materias/ categorías / ODS
Instituto de Investigación Tecnológica (IIT)
Palabras Clave

Voltage collapse, Critical load margin, Continuation power flow, Non-linear
Collections
  • Artículos

Repositorio de la Universidad Pontificia Comillas copyright © 2015  Desarrollado con DSpace Software
Contact Us | Send Feedback
 

 

Búsqueda semántica (CKH Explorer)


Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsxmlui.ArtifactBrowser.Navigation.browse_advisorxmlui.ArtifactBrowser.Navigation.browse_typeThis CollectionBy Issue DateAuthorsTitlesSubjectsxmlui.ArtifactBrowser.Navigation.browse_advisorxmlui.ArtifactBrowser.Navigation.browse_type

My Account

LoginRegister

Repositorio de la Universidad Pontificia Comillas copyright © 2015  Desarrollado con DSpace Software
Contact Us | Send Feedback