• English
    • español
  • español 
    • English
    • español
  • Login
Ver ítem 
  •   DSpace Principal
  • 1.- Docencia
  • Ciencias Humanas y Sociales
  • Doble Grado en Psicología y Criminología
  • KPC-Guías Docentes
  • Ver ítem
  •   DSpace Principal
  • 1.- Docencia
  • Ciencias Humanas y Sociales
  • Doble Grado en Psicología y Criminología
  • KPC-Guías Docentes
  • Ver ítem
JavaScript is disabled for your browser. Some features of this site may not work without it.

Submodelling approach to screw-to-bone interaction in additively manufactured subperiosteal implant structures

Thumbnail
Ver/
Neuropsicología.pdf (182.1Kb)
Neuropsicología.pdf (175.8Kb)
IIT-22-267R_preview (3.556Kb)
Fecha
2023-02-01
Autor
Castrillo, Gabriel
Carnicero López, Alberto
Perera Velamazan, Ricardo
Director/Coordinador
Montes Gan, María Victoria
Pardos Veglia, Alexandra
Yubero Pancorbo, Raquel
Estado
info:eu-repo/semantics/publishedVersion
Metadatos
Mostrar el registro completo del ítem
Mostrar METS del ítem
Ver registro en CKH

Refworks Export

Resumen
 
 
Thanks to new digital technologies, complex cases of severe maxillary atrophy may now be treated with additively manufactured subperiosteal implant structures (AMSISs). However, there are few studies addressing this topic and most of them focus on the mechanical behaviour of the AMSIS itself without considering its interaction with the maxilla bone. The aim of this study is to provide a methodology based on finite element analysis (FEA) to evaluate the effect of interaction between the maxilla bone and the screws fixing the AMSIS. The mechanical performance of an AMSIS was examined via a FEA based on submodelling. Significant differences were encountered in displacements and reaction forces when bone–screw interaction was considered. Stress in the cortical layer was found to be close to the maximum strength while the trabecular layer seems to have no effect on the results; stresses in the AMSIS are lower than the fatigue stress limit. Finally, the comparison of stresses between models with and without osseointegration shows how stresses drop once osseointegration is complete. The proposed submodelling approach considerably reduces the computational effort and enables both a detailed model of the interaction between the thread of the screws and the bone and an accurate evaluation of displacement and stress fields on the interface. The results have shown that stresses in the cortical bone are highly affected by the initial geometry of the thread inside the bone, which demonstrates the importance of modelling the effect of the thread.
 
URI
https:doi.org10.1002cnm.3672
Submodelling approach to screw-to-bone interaction in additively manufactured subperiosteal implant structures
Tipo de Actividad
Artículos en revistas
Créditos
6.0
ISSN
2040-7939
Materias/ categorías / ODS
Instituto de Investigación Tecnológica (IIT)
Palabras Clave

ad hoc prosthesis, AMSIS, dental implant, finite element method, screw-to-bone contact, submodelling, subperiosteal implant structures
Colecciones
  • KPC-Guías Docentes
  • KP2-Guías Docentes
  • Asignaturas

Repositorio de la Universidad Pontificia Comillas copyright © 2015  Desarrollado con DSpace Software
Contacto | Sugerencias
 

 

Búsqueda semántica (CKH Explorer)


Listar

Todo DSpaceComunidades & ColeccionesPor fecha de publicaciónAutoresTítulosMateriasPor DirectorPor tipoEsta colecciónPor fecha de publicaciónAutoresTítulosMateriasPor DirectorPor tipo

Mi cuenta

AccederRegistro

Repositorio de la Universidad Pontificia Comillas copyright © 2015  Desarrollado con DSpace Software